Chapter 6: Calibration
23
5.
Measure the distance between the two points on a chart.
6.
The correction factor (CF) can now be calculated.
CF
= Charted Distance
Average Distance
Enter calibration factor (CF)
1.
Press Display and
for 2 seconds until CAL is displayed.
Cal.
DISPLAY
TM
SPEED
TRIP
TOTAL
MAXIMUM
AVERAGE
D590
2.
Press Display until Log Cal is shown in the window.
Cal.
DISPLAY
TM
SPEED
TRIP
TOTAL
MAXIMUM
AVERAGE
D595
3.
Press
or to enter the calculated correction factor.
Cal.
DISPLAY
TM
SPEED
TRIP
TOTAL
MAXIMUM
AVERAGE
D596