Table 2-15 describes the meaning of the colored quality indicator. In the Synapsis Service
Tool in the menu item
Ship Parameter
, the
General Presentation Standard
shows the
predefined edition of the IEC 62288 for the used system.
Table 2-15
Sensor Quality Indicators
Quality
Indicator
(IEC 62288
edition 1)
Quality
Indicator
(IEC 62288
edition 2)
Description
(no indication)
(no indication)
The sensor has good integrity (edition 1 conditions
GREEN
).
The sensor has good integrity (edition 2 conditions
GREEN
).
(orange)
(yellow)
The sensor has doubtful integrity. Data from this sensor can
be used carefully, but not for automatic control functions
(edition 1 conditions
ORANGE
).
The sensor has doubtful integrity. Data from this sensor can
be used carefully, but not for automatic control functions
(edition 2 conditions
YELLOW
).
Please note:
If there is only one source for a certain type of data, this
source has doubtful integrity. In this case, doubtful integrity is
not a marker for an error
(red)
(yellow)
The sensor failed the integrity test (edition 1 conditions
RED
).
The sensor failed the integrity test (edition 2 conditions
YELLOW
).
(red)
(orange)
No valid and plausible data available from the sensor (edition
1 conditions
RED
and for edition 2 conditions orange).