NautoPilot® 5000 Series
102-890.NG001-NG003
Operator Manual
Edition: 003
87
10000001052
2.3.6.3
RoT & Radius
RoT
Use the + and - softkeys to adjust the max. turn rate for a heading/course
change. Press the SET button to transmit this value to the controller.
Value range: 5
/min to 500
/min (in increments of 1
/min).
Radius
Use the + and - softkeys to adjust the min. radius for a heading/course change.
Press the SET button to transmit this value to the controller.
Value range: 0.1 NM to 5.0 NM (in increments of 0.1 NM).
(NM = Nautical mile)
Selected
Use this pull-down menu to select a heading/course change mode.
This function is identical to the Rad/RoT softkey; see the first display of Figure 22.
Note:
Rad/Rot is not adjustable in mode Track Control with RAYTHEON
Anschütz ECDIS
Figure 52: RoT & Radius (Page function)