Magnetic Sonde
7 Installation and Maintenance
4423
26
Edition:003
Procedure
Fig. 11: Remove Holder with Magnetic Sonde
1
Gap
2
Glass Pane
3
Holder Plate
1. Turn the magnetic compass upside down, see related documentation.
2. Protect the magnetic compass from turning back.
3. Disconnect the magnetic sonde from the related system or equipment.
4. Position the operating tool to the gap (
CAUTION!
Hazard due to too much pressure on the glass pane
Risk of material damage
• Avoid too much pressure to the glass pane.
CAUTION!
Hazard due to damage the magnetic sonde
Risk of material damage
• Take care the holder with the magnetic sonde does not fall down.
5. Remove the holder from the glass pane by moving the operating tool carefully towards
the center of the magnetic compass.