Technical
Data
6
Marathon
Series
FA/FR
Warm
up
Period
15
minutes
Weight
Optical
Head
100
g
(3.5
oz)
Electronics
Housing
710
g
(9
oz)
3.3
Electrical
Specifications
Power
Supply
24
VDC
±20%,
500
mA
(max
100
mV
peak
to
peak
of
ripple)
Power
Consumption
max.
12
W
Output
Isolation
500
V
AC
or
DC
provided
by
manufacturer
supplied
power
supply
accessory
Dielectric
Withstand
Voltage
500
V
Outputs
Analog
0
‐
20
mA,
4
‐
20
mA,
16
bit
resolution
max
current
loop
impedance:
500
Ω
Digital
RS485
networkable
to
32
sensors
Baud
rate:
300,
1200,
2400,
9600,
19200,
38400
(default)
Adjustable
baud
rate
only
available
through
2
‐
way
RS485.
Data
format:
8
bit,
no
parity,
1
stop
bit,
Software
selectable
4
‐
wire,
full
‐
duplex
non
‐
multidrop,
point
‐
to
‐
point
or
2
‐
wire
half
duplex
multidrop
Relay
Contacts
max.
48
V,
300
mA,
response
time
<
2
ms,
(software
programmable)
Input
External
Reset
TTL
input,
trigger
for
resetting
peak
or
valley
hold
Figure
1:
External
Reset
Wiring
Diagram
Sensor
Trigger
GND