8.3.1 Enter Tap Changer Data by Wizard
Touch at ‘Info’ Menu the button besides “U Nom” to enter tap changer data manually or by
wizard.
8.3.2 Enter Tap Changer Data manually
You can anytime enter corresponding voltages to taps manually. You may use this for
instance when your tap steps are not linear. Just push on the filed you like to edit. The editor
works for designator and voltage.
90100-2.20 Instruction Manual TR-MARK III 250V
Page 41 of 68
Touch here for
designator
Touch here for
voltage