Raytech USA, Inc. All rights reserved
16
BASIC INSTRUCTION
–
QUICK TEST:
12
–
0
WARNINGS!
BEFORE OPERATING THIS OR ANY OTHER TEST EQUIPMENT READ ALL SAFETY
WARNINGS AND UNDERSTAND THEM FULLY.
WARNINGS!
BEFORE USING THE BASIC OPERATING INSTRUCTIONS THE OPERATOR SHOULD
BE COMPLETELY FAMILIAR WITH THE TEST SYSTEM AND THIS TYPE OF TESTING.
OPERATION:
12
–
1
This section outlines the basic measurement instruction, step by step, for the MC2.
These are basic instructions, simplified, for the trained and qualified operator.
1. Connect the test leads (2 Current / 2 Potential) to an un-energized device to be measured.
2. Connect the Safety Ground on the front panel to known good Earth Ground.
3. Turn on the system.
4. Turn the Rotary knob to select the Resistance Range / Current Range.
5. Press the rotary knob once.
6. Turn the Rotary knob to (highlight) select the required test: Single, Continuous, Automatic.
7. Press the rotary knob once and the system will perform the test.
8. Save or print the data.