1. Safety instructions

1.  Read this leaflet carefully before commencing to install the SPARTAN unit and retain it 

for future use. Installation can only be carried out by suitably qualified personnel.

2.  Check  the  certification  to  ensure  that  the  Zone,  mains  supply,  ambient  temperature 

present and ‘T’ rating are suitable for the environment the unit is being installed in.

3.  If the SPARTAN unit is to be installed in areas of high vibration, please consult with Raytec.

4.  The SPARTAN unit housing is constructed from marine grade aluminium and toughened 

glass, gaskets are silicone sponge, black encapsulant and o rings are silicone rubber, 

inner domes on LEDs are polycarbonate. The end user must ensure that these materials 

are suitable for the environment the SPARTAN unit will be installed in; Zone 1 and Zone 2 

Hazardous areas.

5.  Check certification nameplate on side of floodlight/highbay to ascertain type of threaded 

cable  entry  on  the  luminaire.  Select  suitably  certified  ATEX/IEC  Ex  cable  glands  and 

stopper plugs, these must be parallel thread, have a minimum of 5 full thread engagement 

and be of a medium/fine tolerance to ISO965-1 and ISO965-3. The cable entry devices 

selected must maintain the IP rating of the luminaire

6.  The incoming mains cable should not exceed a temperature rise of 20°C above the 

ambient conditions; select suitable cable. 

7.  To ensure the safety of the equipment, ensure that the ‘flamepath’ on Zone 1 variants 

are free from any corrosion. No repairs are possible to flameproof joints – if in doubt 
please consult the manufacturer.

8.  External fasteners must have a yield strength of at least 600N/mm2 

9.  On Zone 1 variants the LED assembly contains no user serviceable parts, the luminaire 

must not be operated without all the individual LED polycarbonate covers in position, the 
IP66 rating must be maintained.

    

!

Install in a well 

ventilated area

Do not continually 

stare at lamp

Isolate mains before  

removing cover

1.5m

Summary of Contents for SPARTAN HP series

Page 1: ...tructions 2 Installation 3 Maintenance 4 Technical Specification 5 Trouble Shooting The SPARTAN HP series of explosion protected floodlights highbay are specialist devices certified for use in specifi...

Page 2: ...certification nameplate on side of floodlight highbay to ascertain type of threaded cable entry on the luminaire Select suitably certified ATEX IEC Ex cable glands and stopper plugs these must be par...

Page 3: ...ing SPARTAN Unit 1 To meet the requirements of certification a MINIMUM of 2 fixing points must be used the fixing points must be suitable for the conditions of use 2 The line diagrams below are for gu...

Page 4: ...4 www raytecled com UK Europe Tel 44 0 1670 520055 Americas Tel 1 613 270 9990 Mounting SPARTAN Unit Highbay Application 422 16 6 353 13 9 536 21 1 457 18 1 3 0 5 1 33 1 3 172 6 8...

Page 5: ...e cable should be connected to each terminal block connection 7 To use DALI Dimming interface connect the DALI terminals on the terminal block Wire the Mains cable into the terminal block Provision ha...

Page 6: ...ced remove the flameproof cover to get access to the power supply Remove the power supply from the mains terminals then remove LED red and black wires 5 Disposal of packaging SPARTAN units and old LED...

Page 7: ...nameplate on product Input Current 230Vac full load 0 7A 1 4A Consumption 150W 300W Power Factor 230Vac full load 0 97 Mains Frequency 50 60Hz Inrush Current Ipeak 50 53A t 300 s 60A t 300 s Total Ha...

Page 8: ...number of fittings allowed per MCB MCB Type Rating SPZ SPX HP10K 120W Version SPZ SPX HP15K 180W Version SPZ SPX HP20K 240W Version SPZ SPX HP25K 300W Version B 10A 4 3 2 1 B 16A 10 6 4 3 B 20A 12 7...

Page 9: ...0 300 300 281 2 00 300 300 300 2 50 300 300 300 5 Troubleshooting 1 Ensure the two LED boards are correctly wired to terminal block Red to Red Black to Black paired cables 2 Ensure Mains input is corr...

Page 10: ...ent Spartan range of High Power Floodlights Notified Bodies Sira Certification Services 0518 Unit 6 Hawarden Industrial Park Hawarden Deeside CH5 3US Certificate numbers CML17ATEX1148 CML17ATEX4149 IE...

Page 11: ...ety Requirements has been assessed by reference to the following standards IEC 60079 0 2012 IEC 60079 7 2015 IEC 60079 1 2014 IEC 60079 18 2015 IEC 60079 25 2015 IEC 60079 31 2014 IEC 60079 15 2010 An...

Page 12: ...UK Europe T 44 0 01670 520055 hazsales raytecled com Americas T 1 613 270 9990 ushazsales raytecled com www raytecled com...

Reviews: