15
The trigger output can used to switch a signal of up to 24V, switching up to
20mA when on. When the output is logic 1 (on) a current of up to 20mA can
flow. The maximum current must be limited to an absolute maximum of
50mA by the external circuit. The forward voltage is less than 2V.
When the output is logic 0 (off) a voltage of up to 24V can be blocked.
6.4
Ethernet option
The Ethernet connection is 10Base-T and runs at 10Mbits per second.
6.5
Serial option
The RS232 connections are as follows: The communications port should be set
to 115Kbaud, no parity, 8 data bits, and 1 stop bit.
Connecting to the specified pin on a 9-way female D-type allows straight
through connection to a PC COM port.
Signal
Function
Connection pin on a
standard
9 way female D-type
GND
Connected to power
input negative
5
Rx
Receive input to VTR6
3
Tx
Transmit output from VTR6
2