Raytec HYBRID Series Installation Manual Download Page 8

8

INFRA-RED and WHITE-LIGHT

RM/RL 200/100 Models 

(Model shown: RM/RL 100 Premium)

(Not to scale)

Photocell following 

contact - volt free, 

non polarity sensitive 

(Premium PSU only)

Telemetry Input - 

requires zero volt, 

latched input

Photocell Sensitivity

Mains Input

100V to 230V AC

Auto-Sensing

LED Output x2

(Polarity Sensitive)

Power Adjust

Photocell

12V DC power 

output  

(Premium PSU only)

INFRA-RED and WHITE-LIGHT

RM/RL 50/25 Models

(Not to scale)

Power Adjust

Photocell

LED Output x2

(Polarity Sensitive)

Photocell Sensitivity

Telemetry Input - 

requires zero volt, 

latched input

Mains Input

100V to 230V AC

Auto-Sensing

Power Supply Diagrams

 

(Not to scale)

Summary of Contents for HYBRID Series

Page 1: ...1 Illuminator 2 Power Supply PSU illuminators installation guide including IR Covert IR PLATINUM HYBRID and Low Voltage Series LUX MAX and RAYMAX RAYLUX illuminator PSU Overview This installation guid...

Page 2: ...continually stare at lamp Specifications subject to change without notice Installation to be carried out by suitable trained and qualified personnel Bracket Adaptive illumination bolt LED illuminator...

Page 3: ...4 Connect PSU to Mains 5 Mount illuminator Mount PSU Do not position PSU photocell facing illuminator or other direct light sources Photocell monitors ambient lighting conditions Mount PSU on wall fl...

Page 4: ...e if required see PSU diagrams pages 8 9 Max x2 TARGET Position illuminator adjacent to camera and point towards scene Optional night set up for optimum image performance Reduces performance May cause...

Page 5: ...d Bracketry Optional Bracketry Wall Mount Dome Mount Ptz Mount Pole Mount RM RL 25 8 5mm 0 3 25mm 1 23 5mm 0 9 47mm 1 9 48mm 1 9 RM RL 200 150 100 50 72mm 2 8 52mm 2 36mm 1 4 8 5mm 0 3 33mm 1 2 100mm...

Page 6: ...es 113 x 113mm 4 4 x 4 4 RL300 RL200 RL150 RL100 RL50 RL25 Input AC 100 230 universal 120W AC 100 230 universal 80W AC 100 230 universal 60W AC 100 230 universal 40W AC 100 230 universal 20W AC 100 23...

Page 7: ...7A 13 5V Adjustable Power x 10 100 x 10 100 10 100 10 100 Weight x 1 85 kg 4 1lbs x 1 65 kg 3 6lbs 0 9 kg 2lbs 0 8 kg 1 8lbs Dimensions L x W x D x 160 x 160 x 81mm 6 3 x 6 3 x 3 2 x 160 x 160 x 81mm...

Page 8: ...Photocell Sensitivity Mains Input 100V to 230V AC Auto Sensing LED Output x2 Polarity Sensitive Power Adjust Photocell 12V DC power output Premium PSU only INFRA RED and WHITE LIGHT RM RL 50 25 Model...

Page 9: ...of volt free input into photocell following output on top control board and other wire of volt free input into telemetry input on bottom board Other set up options available contact Raytec Photocell U...

Page 10: ...mp Test Check voltage of lamp o p approx 14V 8V for pulsed units Check current of lamp see instructions for correct current setting To check lamp current this must be done while both LED panels are co...

Page 11: ...rounded supply Do not install within 10ft of pool or spa Do not use with dimmers Do not connect two or more power supplies in parallel This product must be installed by a person familiar with the cons...

Page 12: ...12 UK Europe T 44 0 1670 520055 F 44 0 1670 819760 sales rayteccctv com Americas Toll Free T 1 888 505 8335 ussales rayteccctv com www rayteccctv com RRII 13 2 1...

Reviews: