Raypak XFYRE NINETY PLUS 300 Brochure & Specs Download Page 7

7

Boiler Control and 
On-Board Diagnostic Center

Raypak’s XFyre comes equipped with a microprocessor control
center that displays its information on a 2x20 character LCD
display in plain English. All set-up and programming is done at
this interface. Control monitors boiler system status including
safeties, ignition faults and also stores up to 10 reported faults.
The diagnostic center even monitors and reports the flame
strength signal in microamps. Monitor blower speed, BMS
input and all water and air sensors. A normally-open and nor-
mally-closed dry contact alarm relay is provided.

Outdoor Proven 

Raypak is no stranger to the outdoor environment. Our touchpad is 100% waterproof and has been proven and perfected on our
pool products. No guesswork here, just one tough boiler ready to take on jobs that others have to walk away from.

Safety Faults

Condensate Full

Outdoor Sensor

Line Voltage

Blocked Vent

Low Water Level

24 Volt Low

Low Water Flow

Temper Blocking

High Temperature

Flue/Gas Pressure

Supply Thermistor

Return Thermistor

Supply High

Ignition Control Faults

No Flame

Flame Failure

Flame When Off

Fan Speed Error

X

treme Control

Example Diagnostic Fault Report

Diagnostic Information

X

treme Firing Rates

Cascade up to 8 Boilers 
Deliver up to 6.8 Million BTU at a 40:1 turndown rate!

The XFyre comes standard with a built-in Cascading Boiler Control. No other controls to buy, just daisy chain the units together
with CAT 3 or CAT 5 computer network cables 

(not supplied)

that plug into the front mounted communication bus on each unit

(see low voltage wiring box opposite page)

. Designate a Cascade Master Boiler and set all the other boilers as Followers. It’s that sim-

ple! The XFyre has built-in Lead-Lag control. This allows rotation of the starting boiler so all boilers in the system remain active
and the run times remain equal on each unit. Rotation can even be programmed based on time, ensuring equal run times per
unit.




Summary of Contents for XFYRE NINETY PLUS 300

Page 1: ...up to 99 Efficiency Can be vented with PVC 300 500 850 MBTU Models Ultra Low Emissions...

Page 2: ...5 1 turn down ensures efficiency is maintained throughout the firing rate and actually increases during part load right when you want it The XFyre automatically self tunes to accommodate the widest r...

Page 3: ...170MBTU 500 100MBTU 300 60MBTU With this much flexibility XFyre is the right boiler for almost any size job 6 Intake Air Filter Every XFyre comes standard with a front access removable media combusti...

Page 4: ...and Boiler Control Raypak uses German made high quality Dungs gas valves considered the finest modulating gas valves produced today To the right of the gas valve is the boiler computer control center...

Page 5: ...require increased clearances Heater Side Note Current draw Amps is for pump only Water hardness grains per gallon Soft 0 4 Medium 5 15 Hard 16 25 Water above 15gpg requires water softner Model MBTUH...

Page 6: ...TS Minimum Tube Size inch SHL System Head Loss ft based on heater and tank placed no more than 5 ft apart T Temperature rise F P Pressure drop through heat exchanger ft Hydronic Boiler Hot Water Suppl...

Page 7: ...tdoor Sensor Line Voltage Blocked Vent Low Water Level 24 Volt Low Low Water Flow Temper Blocking High Temperature Flue Gas Pressure Supply Thermistor Return Thermistor Supply High Ignition Control Fa...

Page 8: ...with 3 Water Sensors up to 5 1 Turndown Outdoor Reset Sensor N A Multiple Boiler Controller TempTracker Mod Hybrid up to 16 boilers Direct Spark Ignition System 1 try 4 try High Low Gas Pressure Swit...

Reviews: