16
Page 1: ...004 Replaces All Previous Versions Part No Model RHP 33 US C LISTED R 9900276 The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components Installation and service personnel are required by some states to be licensed Persons not qualified must not attempt to ins...
Page 2: ...justment of the heat pump 2 For the owner operator to explain the features operation safety precautions and service maintenance of the heat pump The manual also includes system drawings and illustrated replacement parts lists WARRANTY CLAIMS See the enclosed Warranty information For the Warranty to apply proper authorisation MUST be obtained PRIOR to making any repairs This Warranty is VOID if the...
Page 3: ... VI Seasonal Start Up or Annual Check 5 VII Heat Pump Running Time 5 VIII Summer Shutdown 6 IX Freeze Protection 6 X Maintenance 6 XI Troubleshooting 7 Plumbing Diagrams 10 Heat Pump Schematic 11 Control Panel Assembly Replacement Parts List 12 Control Panel Cover Assembly Replacement Parts List 13 Heat Pump Assembly Replacement Parts List RHP 33 14 Limited Warranty Information 15 EXCLUSIVE WARRAN...
Page 4: ...rate continuously Even though it may operate continuously for many hours it will still heat the pool with greater economy than other types of fossil fuel heaters You are advised to put a pool cover over the pool at night and other non use periods This will keep evaporation the cause of the greatest heat loss to a minimum and so greatly reduce overall pool heating costs During warmer weather the po...
Page 5: ...st be high enough to keep it completely free of standing water at all times II Electrical Connections The table below lists the typical electrical power requirements for your heat pump Refer to the unit rating plate below the control panel for precise power requirement for each unit and for ampacity and over current protection requirements All wiring must be in accordance with the AS3000 Wiring Ru...
Page 6: ...lve will be required IV Controls and Indicator Lamps Your heat pump incorporates safety controls and indicators to ensure its safe reliable operation Water Pressure Switch Prevents operation when the pump is OFF The unit requires 35 Kpa minimum pressure Water Temperature Control Pool spa water temperature is controlled by the heat pump thermostat on the unit control panel which contains a switch a...
Page 7: ...essor will stay OFF not heating until weather conditions improve Low Pressure red lamp When lit indicates failure in the refrigeration circuit When this lamp is ON service is required Call the number shown in the CONTACT INFORMATION at the front of this manual V Initial Start Up and Check 1 Verify that the Power lamp is ON and that the pool pump is running and circulating properly 2 Verify that th...
Page 8: ...ump and heat pump shut OFF before the water temperature is raised to the desired level you must lengthen the running time of both To do this reset the time clock dial for the longer running time or manually operate the pump with the timer override switch Since the pool heat pump capacity and efficiency are both greater at higher ambient air temperatures run time should be set to take advantage of ...
Page 9: ...alves and remove the internal drain plug Use air pressure to remove water from the bypass assembly and heat exchanger 4 Leave the drains open until the unit is started in the spring 5 Cover the heat pump with a waterproof cover Continuous Pump Operation It is also possible in some areas to prevent heat pump freeze damage by operating the pump continuously during freezing weather However this resul...
Page 10: ...amps on the front control panel see page 4 can provide valuable clues as to what is wrong and may even indicate precisely what the problem is Always observe these lamps before calling a service representative By reporting on the telephone which lamps are ON and OFF the service rep may be able to solve the problem without the expense of a service call A UNIT IS RUNNING BUT NOT HEATING Is the ejecte...
Page 11: ... waited 6 minutes for the time delay After the unit has been running and then shut OFF for any reason there is a 6 minutes timed cycle before operation can begin again Is the Water Flow lamp OFF This lamp will turn OFF if not enough water is flowing through the heater Improperly positioned valves or a dirty filter could decrease the flow of water required for efficient operation When the Water Flo...
Page 12: ...ring an electrician WATER FLOW Verify that the filter is clean to provide good flow Verify that the valves are properly positioned If the Water Flow lamp on the control panel still does not light and water is circulating in the pool or spa contact the installing dealer to adjust the valves TIME CLOCK ADJUSTMENT Verify that the time clock is set to permit the heater to run long enough to heat prope...
Page 13: ...orinators Water In from pool or Spa Water Out to pool or Spa Filter For systems with pumps of 2 HP 1 5Kw or greater over 300 l min an external bypass is required Adjust the bypass valve to divert a minimum of 150 l min gpm through the heat pump Connections are 50mm pipe slip Plumb the heat pump after the filter and before any chlorinators Water In from pool or Spa Water Out to pool or Spa Filter 1...
Page 14: ... P w o L p m e T a p S p m e T l o o P W S a p S l o o P 2 E n o m m o C r o s n e S p m e T r o s n e S p m e T S C E C 1 E C N n o m m o C O C T l o o P O C T a p S O C T l a t o T e t o m e R n o m m o C e t o m e R a p S e t o m e R l o o P e t o m e R e l p r u P k c a l B n w o r B n e e r G C A V 0 4 2 C A V 8 0 2 e u l B d e R k c a l B k n i P n a T k c a l B e t i h W e t i h W n a T k c...
Page 15: ...1 1 Control Panel 2 1 Contactor Compressor 3 1 Fan Relay 4 1 Control Board 24Volt 5 1 Thermostat 6 1 Transformer 7 1 Timer IMC 203 8 1 Capacitor 9 1 Pressure Switch Water 10 1 Fuse Block 11 2 Bushing Heyco 2184 12 4 Stand off RLCBSR1 13 2 Terminal Strip 14 1 Clamp Capacitor 04 15 1 Ground Lug 16 1 Fuse 2A Type 3AG 12 ...
Page 16: ...nt Parts List 1 4 4 4 7 6 7 6 8 8 5 Front ITEM QTY DESCRIPTION PART No 1 1 Control Panel Cover 2 2 POT 3 1 Switch Type A403 4 3 Knob 5 1 Label Control Panel 6 2 Lamp Green 7 2 Lamp Red 8 2 Lamp Amber 2 3 2 RHP Control Panel Cover 1 Back 13 ...
Page 17: ...1 1 Assembly Base 2 1 Evaporator Coil 3 1 Access Panel 4 1 Power Input Panel 5 1 Cover Top 6 1 Compressor Scroll 7 3 Corner Support 8 1 Heat Exchanger 9 2 Retainer Screen 10 1 Control Panel Cover 11 1 Fan Guard 12 1 Fan Blade 13 1 Fan Motor 14 1 Water Manifold Assembly 15 1 Conduit Fan 16 1 Coil Guard 17 1 Control Panel Assembly 18 1 Expansion Valve 19 1 Filter Dryer BFK 165 S 14 ...
Page 18: ...15 ...
Page 19: ...16 ...