42

CALL OUT

DESCRIPTION

207A

266L/267A

337A

399L/407A

BB

BURNER TRAY***

1-B

Burner Tray w/Burners (0-5000)

010343F

010344F

010345F

010346F

Burner Tray w/o Burner (0-5000)

010084F

010085F

010086F

010087F

2-B

Burner Hold Down Kit

010254F

010255F

010256F

010257F

3-B

Burner

017045F/3

017045F/4

017045F/5

017045F/6

4-B

Burner Orifice Nat. #26 (0-5000)*

351632/3

351632/4

351632/5

351632/6

Burner Orifice Nat. #27 (above 5000 ft.)*

351633/3

351633/4

351633/5

351633/6

8-B

Combustion Air Seal Gasket

016361F

016361F

016361F

016361F

5-B

Blower

010042F

010042F

010042F

010042F

7-B

Cooling Fan

010871F

010871F

010871F

010871F

6-B

Combustion Air Orifice Plate

010338F

010339F

010340F

010341F

C

CONTROLS

1-C

006725F

006725F

006725F

006725F

2-C

600892B

600892B

600892B

600892B

3-C

600893B

600893B

600893B

600893B

4-C

013464F

013464F

013464F

013464F

5-C

013640F

013640F

013640F

013640F

8-C

013733F

013733F

013733F

013733F

6-C

009577F

009577F

009577F

009577F

7-C

008062F

008135F

010354F

010355F

9-C

High Limit Auto Reset 135°F Deg Surface Mount

AGS 135°F (Auto Gas Shutoff) - Red Epoxy

 

- prior to 12/2019

 

High Limit 140°F - Black Epoxy

 

- prior to 12/2019

P.

 

C. Board/Control

LCD Display

    Units manufactured from 5/2011

Fuse 5 AMP

Temperature Sensor 

Blower Pressure Switch

High Limit Auto Reset 150F

 Surface Mount (ASME Only)

018304F

018304F

018304F

018304F

G

GAS VALVE

1-G

Combination Valve - Gas On/Off -Nat 

010329F

010329F

010329F

010329F

HP

HEAT EXCHANGER - POLYMER

1-HP

Heat Exchanger Assy Copper

    Units manufactured from 10/2019

017994F

017995F

017996F

017997F

    Units manufactured prior to 10/2019

010043F

010044F

010045F

010046F

Heat Exchanger Assy Cupronickel ***

    Units manufactured from 10/2019

017998F

017999F

018000F

018001F

    Units manufactured from 7/2013 thru 9/2019

014926F

014927F

014928F

014929F

    Units manufactured prior to 7/2013

010356F

010357F

010358F

010359F

2-HP

Inlet/Outlet Header Complete
    Units manufactured from 10/2019

017959F

017959F

017959F

017959F

    Units manufactured from 7/2013 thru 9/2019

006827F

006827F

006827F

006827F

Inlet/Outlet Header (Includes 6-HP)

    Units manufactured from 10/2019

017965F

017965F

017965F

017965F

    Units manufactured from 7/2013 thru 9/2019

014648F

014648F

014648F

014648F

3-HP

Return Header (Includes 6-HP)

015095F

015095F

015095F

015095F

4-HP

Tube Bundle Copper **

010059F

010060F

010061F

010062F

Tube Bundle Cupronickel **

    Units manufactured from 7/2013

014930F

014931F

014932F

014933F

    Units manufactured prior to 7/2013

010364F

010365F

010366F

010367F

5-HP

Baffle (Copper Heat Exchanger)

010038F

005261F

010040F

010041F

Baffle (Cupronickel Heat Exchanger)

    Units manufactured from 6/2013

014934F

014935F

014936F

014937F

    Units manufactured prior to 6/2013

010038F

005261F

010040F

010041F

6-HP

Flange Nut Kit

008259F

008259F

008259F

008259F

7-HP

O Ring Gasket (2)

006713F

006713F

006713F

006713F

8-HP

Sensor Adapter Digital Electronic

006714F

006714F

006714F

006714F

9-HP

Bypass Kit

006715F

006715F

006715F

006715F

10-HP

Bypass Valve

006716F

006716F

006716F

006716F

11-HP

Bypass Dam / Shaft

006717F

006717F

006717F

006717F

12-HP

Bypass Spring (All Sizes Included)

006718F

006718F

006718F

006718F

13-HP

Unitherm Governor 

006719F

006719F

006719F

006719F

14-HP

Unitherm Governor Plug

006720F

006720F

006720F

006720F

15-HP

Drain Plug

006721F

006721F

006721F

006721F

16-HP

Inlet/Outlet Header Dam

N/A  Use 19-HP N/A  Use 19-HP N/A  Use 19-HP N/A  Use 19-HP

17-HP

2" CPVC Connector & Nut (2)

006723F

006723F

006723F

006723F

18-HP

O Ring (2)

006724F

006724F

006724F

006724F

19-HP

Inlet/Outlet Header Baffle w/Header Dam

006826F

006826F

006826F

006826F

20-HP

ProTek Shield

TM

 Assy

017960F

017960F

017960F

017960F

*FOR INSTALLATIONS AT OVER 5,000 FEET ABOVE SEA LEVEL, CONSULT THE FACTORY
**WARNING: The Hydraulic conditions or water chemistry that caused the tube bundle to fail have very likely also damaged the bypass valve and Unitherm

Governor.  We recommend you replace the Unitherm Governor and inspect the bypass assembly.  Failure to do so could cause premature failure of this

replacement part.
***Unless otherwise specified at the time the order is placed, replacement burner trays will be configured for natural gas at sea level.

Summary of Contents for 207A

Page 1: ...other appliance To do so may result in an explosion or fire WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immed...

Page 2: ...See page 15 for flow rate values GAS Distance to regulator pipe lengths and gas inlet sizes See page 14 Required pressure for Natural Gas Min 5 WC Max 10 5 WC Sediment trap is required for all install...

Page 3: ...ve 17 Auxiliary Bypass Valve Adjustment 17 Pressure Relief Valve Installation 17 Plumbing Diagram 18 Heat Exchanger Reversal 19 5 ELECTRICAL WIRING 19 Electrical Power Draw 20 Transformer Wiring 20 6...

Page 4: ...uld cause severe personal injury death or substantial property damage if ignored ACAUTION Indicates the presence of hazards or unsafe practices which could cause minor personal injury or product or pr...

Page 5: ...and dissolved solids in the water become too high scale NOTE It is recommended that the pump be run at least 5 minutes after the heater has been turned off This helps in taking away residual heat from...

Page 6: ...eet 1524 m elevation For elevations above 5 000 feet 1524 m consult the factory F10639 1 THE MODEL AND SERIAL NO CAN ALSO BE FOUND INSIDE THE BEZEL ABOVE THE DISPLAY MODEL AND SERIAL NO LOCATED ON RAT...

Page 7: ...n side This will enable the heater to be serviced in its installed location that is without movement or removal of the heater Clearances less than these may require removal of the heater to service ei...

Page 8: ...learances to Protected Surfaces Heaters must not be installed under an overhang of less than three 3 0 9 m from the top of the heater Three sides must be open in the area under the overhang Roof water...

Page 9: ...edition of the National Fuel Gas Code U S ANSI Z223 1 or Canada CAN CSA B149 and any local codes that may have jurisdiction The most common approach is the 2 opening method with combustion air opening...

Page 10: ...hor Bracket Use hole closest to unit 4 total 2 x 6 x 1 8 Pallet Anchor Bracket 4 Total Kit 011636 1 4 x 1 3 4 S S Tapcon Bolt and Washer Field Supplied NOTE Use hole closest to unit with washer overla...

Page 11: ...48 13 0 330 10 5 8 270 3 4 2 219 99 238 108 19 8 6 399L 399 116 9 29 737 9 229 58 1 2 1486 14 5 368 12 1 2 318 3 4 2 237 108 N A 21 9 5 407A 256 116 Table G Heater Specifications and Dimensions Specif...

Page 12: ...2 4 m Vent stack shall be at least 5 1 5 m in vertical height above the drafthood outlet The vent cap location shall have a minimum clearance of 4 1 2 m horizontally from and in no case below unless a...

Page 13: ...re under load and no load conditions must be provided for natural gas Gas Pressure Regulator The gas pressure regulator is preset at 3 1 in WC for natural gas The pressure at the gas valve taken with...

Page 14: ...1 1 4 1 1 2 2 20 75 100 378 266L 267A 1 1 4 1 1 2 2 25 95 100 378 337A 1 1 4 1 1 2 2 35 132 100 378 399L 407A 1 1 4 1 1 2 2 40 151 100 378 When flow rates exceed maximum GPM an external auxiliary byp...

Page 15: ...ction can be ordered that will allow a standard ASME unit to comply with the code requirements ProTek Shield Assembly This heater is equipped with a ProTek Shield Assembly located under the inlet conn...

Page 16: ...eratures well below accelerated scaling temperatures F10725 GASKET UG PLUG UNITHERM GOVERNOR Figure 20 Unitherm Governor Polymer F10642 2 UG BYPASS ASSY UNITHERM GOVERNOR Figure 21 Unitherm Governor B...

Page 17: ...tlet and run to a safe place of discharge Drain pipe must be the same size as the valve discharge connection throughout its entire length and must pitch downward from the valve No shutoff valve shall...

Page 18: ...IPING SYSTEM BY A PROFESSIONAL ENGINEER Figure 29 Single Pool Heater Installation THIS DIAGRAM IS A RECOMMENDATION AND IS NOT INTENDED TO REPACE AN ENGINEERED PIPING SYSTEM BY A PROFESSIONAL ENGINEER...

Page 19: ...ch access panels to the opposite sides For instructions on reversing the heat exchanger connections on ASME models call your factory representative 5 ELECTRICAL WIRING NOTE If it is necessary to repla...

Page 20: ...LACK BLACK BLACK GREEN GREEN WHITE WHITE WHITE GROUND Figure 32 120 VAC Wire Connection Models 240 VAC Wiring For 240 VAC input power to the unit connect the black wire to the L1 or hot leg of the pow...

Page 21: ...21 6 WIRING DIAGRAM...

Page 22: ...l panel 3 Rotate control panel down until panel stops Do not force NOTE Caution must be used to not damage controls or wiring F10647 3 KNURLED SCREW Figure 36 Knurled Screw Location Control Adjustment...

Page 23: ...d UP buttons simultaneously for 3 to 5 seconds The heater will continue to operate while in the Service Menu The first screen displayed is the Flame Strength indicator which indicates the pilot flame...

Page 24: ...mum Adjustment Refer to step one above to access the program screen Press the MODE button until SPA MAX TEMP appears on the digital display Using the UP and DOWN buttons will change the Maximum Temper...

Page 25: ...t clear Clock Fireman Sw Time clock fireman switch circuit is open Low Temp Lockout Water temperature below 36 F 2 C Table N Heater Status Messages Active Faults The following conditions are displayed...

Page 26: ...Heating in the POOL Mode Heating in the SPA Mode Remote Mode Figure 45 Remote Control Menu Remote Operation Activating the Remote To activate or deactivate the remote function 1 Press and hold the UP...

Page 27: ...e nut on unused wire to the Remote Interface Harness 7 Install the 7 Pin Remote Interface Harness to the P8 connector and turn power ON to the heater See Figure 48 For activation of the remote control...

Page 28: ...ure switch is closed use a multimeter to check If the pressure switch fails to close either the switch setting is too high or not enough pressure is being supplied by the filter pump 4 Turn the heater...

Page 29: ...imit Switches High Limit Removal 1 Shut off main electrical power switch to heater 2 Remove inlet outlet sheet metal access panel 3 Remove defective high limit and replace with the correct new high li...

Page 30: ...combustion blower to blower box 6 Reverse above procedure to reinstall Heat Exchanger Removal 1 Shut water gas and electricity off close valves and relieve pressure then remove relief valve Remove si...

Page 31: ...cleaning spills use wet sweeping or High Efficiency Particulate Air HEPA filtered vacuum to minimize airborne dust Use feasible engineering controls such as local exhaust ventilation or dust collecti...

Page 32: ...ating occur or the gas supply fail to shut off turn off the manual gas control to the appliance Visual Inspection Flames can be observed through the opening below the plenum Flame color is blue and ev...

Page 33: ...nd to replace any part of the control system and any gas control which has been under water 1 STOP Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electrica...

Page 34: ...y look to see if the filter pressure is higher than usual 4 The pump may have lost its prime and be running dry Check the pressure on the filter If there is no pressure then you are not moving water o...

Page 35: ...lazy flame Low gas pressure Adjust gas pressure Insects or debris clogging burner intake ports Clean burners Outer jacket very hot paint blistered Broken refractory caused by shipping damage or improp...

Page 36: ...en PC board and pilot operator on gas control Check for 24 VAC across PV MV PV terminals on PC board If voltage is okay replace gas control if not replace PC board NOTE If PC board goes into lockout r...

Page 37: ...15 21 27 32 38 41 Resistance k 261 1 199 0 153 1 118 8 93 0 73 3 58 3 51 0 If okay replace Circuit Board Sensor Failure Inspect thermistor wires and connector at Terminal P1 Check resistance value of...

Page 38: ...ent under standard company warranties must be properly tagged with a return parts tag completely filled in with the heater serial number model number etc and shipped to the Company freight prepaid If...

Page 39: ...C 8 C 14 S 15 M 25 M 20 HP 3 V 1 V 2 V 9 M I S I3 S 2 S 5 HP 4 HP 7 HP 6 HP I2 S 6 HP I5 HP 3 HP 7 S 4 S 17 HM 11 S 4 C 6 M 8 S 8 M 7 M 3 S 3 B 4 B 1 G 10 S 1 B 2 B 2 M 3 J 10 M 6 B 5 B 7 C 1 J 4 S 5...

Page 40: ...AVAILABLE ON ASME HEATERS UNTIL END Q3 2020 FOR UNITS WITH ASME CAST IRON HEADERS PRIOR TO 12 2019 16 HM 15 HM 12 HM 9 HM 10 HM 2 C 6 M 11 HM 8 HM OPTIONAL 1 M 3 C 6 C 5 HM 17 HM 14 HM 13 HM 2 HM 4 H...

Page 41: ...EK ADPTER AND POLYMER UNITS PRIOR TO 10 2019 6 M 17 HP 14 HP INLET 13 HP 2 HP 10 HP 12 HP 11 HP 16 HP 1 C 1 M 6 C 19 HP 19 HP 8 HP 15 HP 18 HP OPTIONAL 18 HP 23 M OUTLET 24 M 29 HM 27 HM 22 M 26 HM 24...

Page 42: ...7 2013 thru 9 2019 006827F 006827F 006827F 006827F Inlet Outlet Header Includes 6 HP Units manufactured from 10 2019 017965F 017965F 017965F 017965F Units manufactured from 7 2013 thru 9 2019 014648F...

Page 43: ...o 12 2019 010055F 006733F 010057F 010058F Tube Bundle Cupronickel ASME Units manufactured from 12 2019 017978F 017979F 017980F 017981F Units manufactured prior to 12 2019 010368F 010369F 010370F 01037...

Page 44: ...87F 9 M Gasket Insulation Swaybrace Jacket Top 010350F 010350F 010350F 010350F 10 M Blower Air Pressure Switch Sample Tube 010348F 010348F 010348F 010348F 11 M Touch up Paint Green 750125 750125 75012...

Page 45: ...Header 010311F 010311F 010311F 010311F Access Panel Set ASME Access Panel Set 3 Pcs for BR Header from 12 2019 017967F 017967F 017967F 017967F Access Panel Set 3 Pcs for CI Header prior to 12 2019 01...

Page 46: ...46 NOTES...

Page 47: ...47 NOTES...