OPERATING AND
INSTALLATION
INSTRUCTIONS

Models

185, 265, 335, 405

Swimming Pool and Spa Heaters

181/182, 260/261, 330/331, 400/401

Water Heaters and Boilers

D-2 POWER VENT

(FOR ELECTRONIC IGNITION MODELS ONLY)

CATALOG NO. 6000.57D
Effective:

        10-26-06

Replaces:         03-15-03

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids or other combustible
materials in the vicinity of this or any other appliance. To do so may result in an explosion
or fire.

WARNING:

 Improper installation, adjustment, alteration, service or maintenance can cause

property damage, personal injury or loss of life. Refer to the user’s information manual
provided with this heater. Installation and service must be performed by a qualified in-
staller, service agency or the gas supplier.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS:
·

Do not try to light any appliance.

·

Do not touch any electrical switch; do not use any phone in your building.

·

Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.

·

If you cannot reach your gas supplier, call the fire department.

This manual should be maintained in legible condition and
kept adjacent to the appliance or kept in a safe place for
future reference.

P/N 241086 Rev. 1

Summary of Contents for 185

Page 1: ...n service or maintenance can cause property damage personal injury or loss of life Refer to the user s information manual provided with this heater Installation and service must be performed by a qual...

Page 2: ...D 2 Power Vent If there are any questions which this manual does not answer please contact your local Raypak Representative THIS MANUAL SHOULD BE MAINTAINED IN LEGIBLE CONDITION AND KEPT ADJACENT TO T...

Page 3: ...usly re move the inner stack adapter and replace it with the PowerVent stack adapter Otherwise install the PowerVent stack adapter 4 Unscrew the access panel on the right side of the appliance Set asi...

Page 4: ...and blower motor NOTE The 90 elbow may be used as a termination cap MOUNTING POWER VENT ASSEMBLY continued 11 Mount the PowerVent assembly bottom on the 6 vent Twist the assembly downward Snap the mou...

Page 5: ...he flue gas leakage Care must be taken during assembly to insure that all joints are sealed properly and are airtight The vent must be installed to prevent the potential accumulation of condensate in...

Page 6: ...ng guide or factory The D 2 Power Vent assembly is suitable for through the wall venting and for connection to smaller size vent pipes and breeching other than the standard atmospheric heater The D 2...

Page 7: ...7 185 405 POOL HEATER ATMOSPHERIC...

Page 8: ...8 185 405 POOL HEATER Low NOx...

Page 9: ...9 182 260 WH1 ATMOSPHERIC...

Page 10: ...181 261 WH1 Low NOx 10...

Page 11: ...en the automatic main gas valves will open and the heater will operate When the operating limit circuit is satisfied the heater will shut down 11 Dimensional Data Model A B C D 181 18 13 12 38 7 88 4...

Page 12: ...Turn operating control to end call for heat 6 Wait a minimum of 60 seconds 7 Open pilot gas valve a Repeat procedure outlined in 4 above 8 After pilot gas is proven and main safety shut off valve is...

Page 13: ...ILLUSTRATED PARTS LIST 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Page 14: ...5300 FAX 800 872 9725 Raypak Canada LTD 2805 Slough Street Mississauga Ontario Canada L4T 1G2 905 677 7999 FAX 905 677 8036 Raypak Australia Pty Ltd 7 Geddes St Mulgrave Victoria Australia 3170 6139 5...

Reviews: