Raypak 181/182 Installation & Operating Instructions Manual Download Page 3

Warnings

3

Pay Attention to These Terms

3

Receiving Equipment

4

General Specifications

4

Installation

4

Mounting the Assembly

4

Wiring a Power Vent Assembly to

an Appliance with IID Ignition

7

Venting

7

Wiring Diagrams

9

182-260 H4/WH1 (Atmospheric)

9

181-261 H4/WH1 (Low NOx)

10

330-400 H4/WH1 (Atmospheric)

11

331-401 H4/WH1 (Low NOx)

12

Sequence of Operation

14

Start Up Procedures

14

Draft Proving Switch

14

Illustrated Parts List

15

CONTENTS

3

DANGER:

Indicates the presence of immediate hazards which will cause severe

personal injury, death or substantial property damage if ignored.

WARNING:

Indicates the presence of hazards or unsafe practices which could cause

severe personal injury, death or substantial property damage if ignored.

CAUTION:

Indicates the presence of hazards or unsafe practices which could cause

minor personal injury or product or property damage if ignored.

NOTE:

Indicates special instructions on installation, operation, or maintenance which

are important but not related to personal injury hazards.

WARNINGS

Pay Attention to These Terms

NOTE:

Minimum 18 AWG, 105°C, stranded wire

must be used for all low voltage (less than 30 volts)

external connections to the unit. Solid conductors

should not be used because they can cause

excessive tension on contact points. Install conduit

as appropriate. All high voltage wires must be the

same size (105°C, stranded wire) as the ones on the

unit or larger.

Summary of Contents for 181/182

Page 1: ...n an explosion or fire WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a...

Page 2: ...8 reflects the following Changes to Fig 2 on page 5 Fig 4 on page 7 Fig 5 on page 8 Dimensional Drawing on page 13 Illustrated Parts List on page 15 Additions Note on page 4 Wiring Diagrams on pages...

Page 3: ...presence of hazards or unsafe practices which could cause severe personal injury death or substantial property damage if ignored CAUTION Indicates the presence of hazards or unsafe practices which co...

Page 4: ...blower with a 120 240 volt 60 Hz 1 0 1 95A 3200 RPM motor a plenum complete with a draft proving switch and a motor relay When provided for field mounting the assembly is equipped with a wire harness...

Page 5: ...t down to the appli ance 10 If the appliance is a 181 182 330 or 331 remove the tabs underneath the power vent using a 5 16 nut driver and relocate them closer to the center of the Power Vent as shown...

Page 6: ...e 4 ft 1 2m below or to side of opening 1 ft 30 cm above opening 3 ft 91 cm K Clearance to mechanical air supply inlet 3 ft 91 cm above if within 10 ft 3m horizontally 6 ft 1 83m L Clearance above pav...

Page 7: ...d through the length of horizon tal run For appliances installed in extreme cold climate it is recommended that a The vent be installed with a slight upward slope of not more than 1 4 per foot of hori...

Page 8: ...ctive controls in the heater control box The harness is of sufficient length to fit the appliance for which it is sized Reference the wiring diagram supplied with each appliance for actual connections...

Page 9: ...9 Wiring Diagrams 182 260 H4 WH1 Atmospheric...

Page 10: ...10 181 261 H4 WH1 Low NOx...

Page 11: ...11 Wiring Diagrams 330 400 H4 WH1 Atmospheric...

Page 12: ...12 331 401 H4 WH1 Low NOx...

Page 13: ...TA Model No A B C D 181 18 13 12 38 7 88 4 25 182 18 13 12 38 7 88 4 25 260 18 13 12 38 7 88 4 25 261 18 13 12 38 7 88 4 25 330 17 50 15 75 7 63 6 00 331 17 50 15 75 7 63 6 00 400 17 50 15 75 7 63 6 0...

Page 14: ...power switch 4 Set operating control to call for heat a Fan motor starts draft proving switch clos es b Heater pump starts flow switch closes c Ignition module energized d Check for spark at gas pilo...

Page 15: ...8 6 8 0 0 x o B e u l F 5 6 Base Assembly 008684F 008685F F 6 8 6 8 0 0 F 6 8 6 8 0 0 r a l l o C e u l F 7 F 8 8 6 8 0 0 F 7 8 6 8 0 0 r o t p a d A e u l F 8 F 9 8 6 8 0 0 F 9 8 6 8 0 0 e g n a l F...

Page 16: ...www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A...