1.  Press and release the “learn” button 

on motor unit. The learn indicator 
light will glow steadily for 30 
seconds.

2.  Within 30 seconds, enter a four digit 

personal identification number (PIN) 
of your choice on the keypad. Then 
press and hold the enter button.

3.  Release the button when the motor 

unit lights blink. It has learned the 
code. If light bulbs are not installed, 
two clicks will be heard.

To Add, Reprogram or Change a Keyless Entry PIN

NOTE:

 Your new Keyless Entry must be programmed to operate your garage door opener.

USING THE “LEARN” BUTTON 

  USING THE SMART CONTROL PANEL

TM

To change an existing, known PIN

If the existing PIN is known, it may be changed by one 
person without using a ladder.

1.  Press the four buttons for the present PIN, then press 

and hold the # button.

   The opener light will blink twice. Release the # button.

2.  Press the new 4-digit PIN you have chosen, then 

press Enter.

The motor unit lights will blink once when the PIN has 
been learned.

Test by pressing the new PIN, then press Enter. The door 
should move.

To set a temporary PIN

You may authorize access by visitors or service people 
with a temporary 4-digit PIN. After a programmed number 
of hours or number of accesses, this temporary PIN 
expires and will no longer open the door. It can be used to 

close

 the door even after it has expired. To set a 

temporary PIN:

1.     Press the four buttons for your personal entry PIN (not 

the last temporary PIN), then press and hold the 

 

button.

   The opener light will blink three times. Release the 

button.

2.  Press the temporary 4-digit PIN you have chosen, then 

press Enter.

  The opener light will blink four times.

3.  To set the number of 

hours

 this temporary PIN will work, 

press the number of hours (up to 255), then press 

.

OR

3.  To set the number of 

times

 this temporary PIN will work, 

press the number of times (up to 255), then press #.

The opener light will blink once when the temporary PIN 
has been learned.

Test by pressing the four buttons for the temporary PIN, 
then press Enter. The door should move. If the temporary 
PIN was set to a certain number of openings, remember 
that the test has used up one opening. To clear the 
temporary password, repeat steps 1-3, setting the number 
of hours or times to 0 in step 3.

1.  Press the PROG <Learn> button on 

the Smart Control Panel

TM

.

2.  Press the PROG <Learn> button 

again to confirm Learn Mode.

3.  Enter a four digit personal 

identification number (PIN) of your 
choice on the keypad. Then press 
enter.

4.  When the motor unit lights blink, it 

has learned the code. If light bulbs 
are not installed, two clicks will be 
heard.

NOTE: 

This method requires two people if the Keyless 

Entry is already mounted outside the garage. 

LOCK

LIGHT

LOCK

LIGHT

One Button Close: 

Opener can be closed by pressing only the ENTER button if the one button close feature has been 

activated. This feature has been activated at the factory. To activate or deactivate this feature press and hold buttons 1 
and 9 for 10 seconds. The keypad will blink twice when the one button close is active. The keypad will blink four times 
when one button close is deactivated.

35

Summary of Contents for Safety Signal 3850RGD

Page 1: ...ation The door WILL NOT CLOSE unless the Protector System is connected and properly aligned Periodic checks of the opener are required to ensure safe operation The model number label is located under...

Page 2: ...e door manually 30 Care of your opener 30 Having a problem Troubleshooting 31 Diagnostic chart 32 Smart Control Panel TM messages 33 Programming 34 35 To add or reprogram a hand held remote control 34...

Page 3: ...Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding...

Page 4: ...d bottom of door must not exceed 1 4 6 mm Wall mounted Door Control Motor Unit ONE PIECE DOOR WITHOUT TRACK Access Door Safety Reversing Sensor Gap between floor and bottom of door must not exceed 1 4...

Page 5: ...age door opener is packaged in two cartons which contain the motor unit and all parts illustrated below Accessories will depend on the model purchased If anything is missing carefully check the packin...

Page 6: ...ead the spring trolley nut on the threaded shaft until it is finger tight against the trolley Figure 1 Do not use any tools Insert a screwdriver tip into one of the nut ring slots and brace it firmly...

Page 7: ...and other hardware MUST be made by a trained door systems technician BEFORE installing opener 4 Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entang...

Page 8: ...he top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possible S...

Page 9: ...age Door Header Wall Garage Door UP CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket UP CEI...

Page 10: ...tach the Rail to the Header Bracket Position the opener on the garage floor below the header bracket Use packing material as a protective base NOTE If the door spring is in the way you ll need help Ha...

Page 11: ...the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place a 2x4 laid flat on the top section beneath the rail If the top secti...

Page 12: ...e bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket 8 Grease the top and underside of the rail surface where the trol...

Page 13: ...ing 1 8 3 mm to protrude above wall surface Position bottom of door control on screw head and slide down to secure Adjust screw for snug fit Drill and install top screw with care to avoid cracking pla...

Page 14: ...til the lens hinge is in the fully open position Do not remove the lens Install a 100 watt maximum light bulb in each socket Light bulb size should be A19 standard neck only The lights will turn ON an...

Page 15: ...codes NEVER use an extension cord 2 wire adapter or change plug in ANY way to make it fit outlet Be sure the opener is grounded Ground Tab Green Ground Screw Ground Wire Black Wire PERMANENT WIRING CO...

Page 16: ...iving eye lens The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be se...

Page 17: ...the lip hugging the back edge of the track Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 3 Place the bracket against the...

Page 18: ...hts in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct The sending eye amber indicator light will glow regardless of alignment or obstruction If...

Page 19: ...g holes Secure the door bracket using the two 1 4 14x5 8 self threading screws Figure 2A Alternately use two 5 16 bolts lock washers and nuts not provided Figure 2B Metal insulated or light weight fac...

Page 20: ...he door if required for your installation Refer to the dotted line optional placement drawing Self Threading Screw 1 4 14x5 8 HARDWARE SHOWN ACTUAL SIZE Header Wall Vertical Centerline of Garage Door...

Page 21: ...ole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm...

Page 22: ...from the inner trolley by pulling straight down on the emergency release handle and sliding the outer trolley back toward the motor unit Connect the curved door arm section to the trolley using the 5...

Page 23: ...ck and purple buttons to reach the desired closed position 7 Push the remote control or the door control Figure 3 This sets the DOWN close limit and should bring the door to the open position If the o...

Page 24: ...n The LED Indicator Light will stop flashing when the force has been learned The opener has learned the forces required to open and close your door The door must travel through a complete cycle UP and...

Page 25: ...cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY CHECK Test the Safety Reverse System after Each adjustment...

Page 26: ...fety SignalTM light feature Lights will also turn on when someone walks through the open garage door With a Smart Control PanelTM this feature may be turned off as follows With the opener lights off p...

Page 27: ...ble the motion sensor when using the opener lights as working lights Otherwise they will turn off automatically if you are working beyond the sensors range Lock feature Designed to prevent operation o...

Page 28: ...tallic surface This allows the sensor to recalibrate itself Dim LED lights Replace two 3V2016 batteries with same type 3V2016 coin cells No rapid LED blinking after pressing a button Replace two 3V201...

Page 29: ...k with local codes for disposal instructions Battery Status LED Standby Power OPERATING INSTRUCTIONS 1 Test the installed battery with the motor unit To test the battery disconnect the motor unit powe...

Page 30: ...y Pull the emergency release handle down and back toward the opener The door can then be raised and lowered manually as often as necessary To disengage the lockout feature pull the handle straight dow...

Page 31: ...fety reverse test after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refe...

Page 32: ...ndicator lights do not light replace the safety reversing sensors Symptom LED is not lit on door control Inspect door control wires for a short staple in wire replace as needed Disconnect wires at doo...

Page 33: ...d on the door control Pressing the Prog LEARN button again will allow the user to program an additional remote control to the opener Meaning This message will appear when the Prog learn button has bee...

Page 34: ...TICE If this Safety SignalTM garage door opener is operated with a non rolling code remote control the technical measure in the receiver of the garage door opener which provides security against code...

Page 35: ...old the button The opener light will blink three times Release the button 2 Press the temporary 4 digit PIN you have chosen then press Enter The opener light will blink four times 3 To set the number...

Page 36: ...ntrol 3 10A19 3V2016 Lithium battery LED and opener 4 10A33 3V2450 Lithium battery proximity switch 5 29C151 Remote control visor clip 6 41A2828 Emergency release rope and handle assembly 7 41B4494 1...

Page 37: ...th screws 4 41A6281 Wire harness kit 5 41D794 Motor with positioning sensor 6 41DB002 2 Receiver logic assembly KEY PART NO NO DESCRIPTION 7 41A6231 End panel with battery door and screw 8 41C190 Tran...

Page 38: ...door opener from outside by entering a password on a specially designed keyboard Also can add a temporary password for visitors or service persons This temporary password can be limited to a programma...

Page 39: ...39 NOTES...

Page 40: ...ot apply to you THIS LIMITED WARRANTY DOES NOT COVER NON DEFECT DAMAGE DAMAGE CAUSED BY IMPROPER INSTALLATION OPERATION OR CARE INCLUDING BUT NOT LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE...

Reviews: