background image

near the conditioner inlet, close it. 2. Relieve water pressure in the conditioner by putting the control in 
the backwash position momentarily. Return the control to the service position. 3. Unplug electrical cord 
from outlet.4. Disconnect the cable from meter assembly. 5. Remove two screws and clips at by pass 
valve or yoke. Pull resin tank away from plumbing connections.6. Remove two screws and clips at 
control valve. Pull meter module out of control valve. 7. Apply silicone lubricant to four new o rings and 
assemble to the four ports on new meter module.8. Assemble meter to control valve. Note, meter 
portion of module must be assembled to valve outlet. 9. Attach two clips and screws at control valve. Be 
sure clip legs are firmly engaged over lugs. 10. Push resin tank back to the plumbing connections and 
engage meter ports with by pass valve or yoke. 11. Attach two clips and screws at by pass valve or yoke. 
Be sure clip legs are firmly engaged over lugs. 12. Return by pass or inlet valving to normal service 
position. Water pressure should now be applied to the conditioner, and any by pass line shut off. 13. 
Check for leaks at all seal areas. 14. Plug electrical cord into outlet. 15. Set time of day. Make sure the 
control valve is in the service position. 16. Plug cable into meter assembly. F. Replace Filtrex media 1. 
Approximately every 2 years contact your local Rayne Dealer. 

Owner’s Manual 

Trouble Shooting Guide 

SYMPTOM 

 

Softener fails to 

regenerate automatically. 

  

PROBABLE CAUSE                                       CORRECTION 

Cord plugged into intermittent            A.Connect to constant power 

or dead power source.                                      source. 

Disconnected meter cable. B. Reconnect cable 

Defective power cord. C.Replace cord. 

D.Defective controller or meter.     D.Replace or repair. 

SYMPTOM 

 

Regeneration at wrong time. 

  

  

PROBABLE CAUSE                                                              CORRECTION 

Summary of Contents for 5066

Page 1: ...ing the controller and normal operating maintenance required by the owner for the following units RG 1250 RXD 1000 RXD 1500 RXD 1500D Water Quality Association tested and certified under industry stan...

Page 2: ...RXD 1000 RXDI000S RXD 1500 RXDI500 D Description 1 5066103 RXD Controller Specify Model 2 60049 Bypass plastic 1 3 ST1040 ST1035 ST1047 10 x 40 10 x 35 10 x 47 Mineral Tank 4 RF00011 n a RF00011 Tank...

Page 3: ...02 BR 15 x 17 Black Brine Tank 3 A10171 BR 15 x 17 Black Brine Tank Lid 4 A11510 BR Brine Line 5 A13940 BR Overflow Fitting 6 A14120 BR Brine Well 7 A05300 BR 2 Brine Well Lid 8 2310 500 Brine Valve A...

Page 4: ...241 Spacer 4 5 13242 Seal 5 1 18265 Piston Downflow 6 1 14309 Retainer Piston Rod 7 1 18268 End Plug Assembly 8 3 18261 Screw Hex Washer Head 1024 x 13 16 9 1 18267 Piston Rod 10 1 17978 Brine Valve S...

Page 5: ...Injector Throat specify size 000 00 0 1 2 3 29 1 18274 X Injector Nozzle specify size 000 00 0 1 2 3 30 1 18273 Vortex Generator 31 1 18271 Screen Injector 32 1 18301 Seal Injector 33 1 18277 Cap Inje...

Page 6: ...ontrol Drive Assembly Downflow 3 1 18217 10 Motor Assembly 24V 60 Hz 4 2 13602 Screw Rd Head 6 32 x 5 16 5 2 18261 Screw Hex Head 10 24 x 13 16 6 1 13363 Washer Plain 145 ID 7 4 13296 Screw Hex Washer...

Page 7: ...ription 1 1 19797 Meter Assembly Turbine 2 1 13314 Screw Hex Washer 18 18 x 5 8 3 1 19569 Clip Flow Meter 4 1 19791 01 Meter Cable Assembly Turbine 5 4 13305 0 Ring 119 6 4 14613 Flow Straightener Own...

Page 8: ...1 0 Ring 218 7 2 18662 Retaining Ring 8 2 18660 ORing 9 2 13305 0 Ring 119 10 2 13255 Clip Mounting 11 2 13314 Screw Hex Washer Head 818 5 8 12 1 18706 Yoke Plastic 1 NPT 1 8706 02 Yoke Plastic 3 4 no...

Page 9: ...y a shut off valve near the conditioner inlet close it 2 Relieve water pressure in the conditioner by putting the control in the backwash position momentarily Return the control to the service positio...

Page 10: ...applied to the conditioner and any by pass line shut off Check for leaks at seal around injector cap C To Replace Piston and or Seals and Spacers and or Brine Valve Follow steps A1 through A 5 Remove...

Page 11: ...ng connections and engage meter ports with by pass valve or yoke 11 Attach two clips and screws at by pass valve or yoke Be sure clip legs are firmly engaged over lugs 12 Return by pass or inlet valvi...

Page 12: ...it yearly Salt may be bridged Resin Fouling C Call dealer find out how to confirm it clean the resin and prevent future fouling D Poor distribution Channeling D Call dealer Check uneven bed surface d...

Page 13: ...M High salt usage PROBABLE CAUSE CORRECTION High Salt setting A Adjust salt setting Excessive water in brine tank B See symptom No 7 SYMPTOM Loss of water pressure PROBABLE CAUSE CORRECTION A Scaling...

Page 14: ...ly 20 psig minimum E Timer not cycling E Replace timer SYMPTOM Softener fails to use salt PROBABLE CAUSE CORRECTION A Plugged restricted drain line A Clean drain line and or flow control B Injector is...

Page 15: ...A Faulty timer A Call dealer clean valve rebuild unit B Internal control leak B Same as above Valve jammed in brine C Same as above refill unit Valve motor stopped or jammed D Replace valve motor 600...

Page 16: ...2097 Flow Washer 1 0 GPM 1 12977 0 Ring 015 1 13244 Adapter BLFC 1 13245 Retainer BLFC 6011500 Piston Assembly Downtlow 1 14309 Retainer Piston Rod 1 18265 Piston Downflow 1 18267 Piston Rod 1 18268 E...

Page 17: ...2801 1610 Injector Kit 1 White Model 1000 1500 602802 1610 Injector Kit 2 Blue Model 2000 602803 1610 Injector Kit 3 Yellow 1 18271 Screen Injector 1 18272 XX 1610 Injector Assembly 1 18277 Cap Inject...

Page 18: ...GPM 6070524 DLFC 2 4 GPM Model 1250 6070530 DLFC 3 0 GPM 60705 35 DLFC3 5 GPM 60705 40 DLFC 4 0 GPM 6070545 DLFC 4 5 GPM 6070550 DLFC 5 0 GPM 6070560 DLFC 6 0 GPM 6070570 DLFC 7 0 GPM 1 11183 0 Ring 0...