near the conditioner inlet, close it. 2. Relieve water pressure in the conditioner by putting the control in
the backwash position momentarily. Return the control to the service position. 3. Unplug electrical cord
from outlet.4. Disconnect the cable from meter assembly. 5. Remove two screws and clips at by pass
valve or yoke. Pull resin tank away from plumbing connections.6. Remove two screws and clips at
control valve. Pull meter module out of control valve. 7. Apply silicone lubricant to four new o rings and
assemble to the four ports on new meter module.8. Assemble meter to control valve. Note, meter
portion of module must be assembled to valve outlet. 9. Attach two clips and screws at control valve. Be
sure clip legs are firmly engaged over lugs. 10. Push resin tank back to the plumbing connections and
engage meter ports with by pass valve or yoke. 11. Attach two clips and screws at by pass valve or yoke.
Be sure clip legs are firmly engaged over lugs. 12. Return by pass or inlet valving to normal service
position. Water pressure should now be applied to the conditioner, and any by pass line shut off. 13.
Check for leaks at all seal areas. 14. Plug electrical cord into outlet. 15. Set time of day. Make sure the
control valve is in the service position. 16. Plug cable into meter assembly. F. Replace Filtrex media 1.
Approximately every 2 years contact your local Rayne Dealer.
Owner’s Manual
Trouble Shooting Guide
SYMPTOM
Softener fails to
regenerate automatically.
PROBABLE CAUSE CORRECTION
Cord plugged into intermittent A.Connect to constant power
or dead power source. source.
Disconnected meter cable. B. Reconnect cable
Defective power cord. C.Replace cord.
D.Defective controller or meter. D.Replace or repair.
SYMPTOM
Regeneration at wrong time.
PROBABLE CAUSE CORRECTION