26
Transducers for Fishfinders
Figure 2-9:
Fore View of Transducer Installation
8. If a fairing is used, apply marine sealant to the flat side of the tri-
angular plug. Push the plug into the triangular recess in the fair-
ing. The triangular plug fits one way only. Be sure the curved
side of the plug is exposed, matching the curve on the outside of
the fairing. Tap it into place with a mallet.
CAUTION:
For smooth water flow over the transducer’s sensor, be sure that
the external surface of the installed triangular plug is FLUSH
with the external curved surface of the fairing.
9. Being sure the valve assembly is seated firmly in the housing,
carefully screw the cap nut in place. Hand tighten it only; do not
over tighten.
10. Remove any excess sealant on the outside of the hull to ensure
smooth water flow over the transducer.
Cable
Safety ring
Safety chain
Pull ring
Retaining pin
Cap nut
Stem
Safety wire
Hull nut
Backing block
Fairing
Hull
Transducer
D4863-2