3.4 Power and drive cables
When determining the cable required for the power and drive
connections it is necessary to consider the combined cable length of
both connections.
A
B
D10454-2
1
2
3
1.
Course computer
2.
Power supply / distribution panel
3.
Drive unit
Power and drive cable selection
Drive
Supply
voltage
Max. length
(A+B)
Cable size
Type 0.5 hydraulic
pump
0–7 m (0–23 ft)
2.5 mm
2
(14 AWG)
• Type 1 drive
• CR pump
(SPX-SOL
only)
12 V
7–10 m
(23–32.8 ft)
4 mm
2
(12 AWG)
Drive
Supply
voltage
Max. length
(A+B)
Cable size
0–5 m
(0–16.4 ft)
6 mm
2
(10 AWG)
12 V
5–7 m
(16.4–23 ft)
10 mm
2
(8 AWG)
0–3 m (0–9.8 ft)
4 mm
2
(12 AWG)
3–5 m
(9.8–16.4 ft)
6 mm
2
(10 AWG)
Type 2 drive
24 V
5–10 m
(16.4–32.8 ft)
10 mm
2
(8 AWG)
12 V
0–5 m
(0–16.4 ft)
10 mm
2
(8 AWG)
0–5 m
(0–16.4 ft)
6 mm
2
(10 AWG)
Type 3 drive
24 V
5–7 m
(16.4–23 ft)
10 mm
2
(8 AWG)
Important:
Use of an incorrect power cable size will reduce the
power supplied to the drive unit and could cause your autopilot to
malfunction. If in doubt, use a heavier gauge cable.
Power and drive connection
Power connection
Power to the course computer must be from an appropriately fused
and rated supply.
24
SPX SmartPilot installation instructions
Summary of Contents for SmartPilot SPX-10
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ...6 SPX SmartPilot installation instructions ...
Page 10: ...10 SPX SmartPilot installation instructions ...
Page 40: ...40 SPX SmartPilot installation instructions ...
Page 44: ...44 SPX SmartPilot installation instructions ...
Page 49: ......
Page 50: ...www raymarine com ...