LifeTag Installation & Commissioning Guide
9
Figure 11 - Fitting buzzer
Figure 12 - Summary of system connections
D8982-1
1.
2.
4.
3.
Mark holes for fixing screws.
Drill two
1/8
inch (3.5 mm) pilot holes.
Secure the safety alarm with the
No. 8 screws provided.
Countersink the pilot holes to prevent
damage to the mounting surface.
Locating
Securing
D8981-1
When you have secured the Base Station and Alarm buzzer, connect the Base Station:
If you want to use the switched 12 V output from the Base Station, connect as described in
Figure 8
.
To the Alarm buzzer.
Alarm buzzer
(see
Figure 7
)
Base Station
(see
Figure 4
)
Connect to SeaTalk
bus (see
Figure 5
)
discard connector then
connect to 12 V dc power
source (see
Figure 6
)
Important:
When connecting any part of the system, refer to the appropriate diagrams under
Connecting Base Station
(above) to ensure you connect correctly.
Either to SeaTalk, or to a separate 12 V power supply.
or
Optional 12 V output
during alarm condition
(see
Figure 8
)
Red
Screen
+
-
Either
5 A Fuse
87064_1.book Page 9 Thursday, April 6, 2006 2:38 PM
Draft copy 06/04/06