background image

IMPORTANT

Please read and follow the instructions on this sheet when installing your Raymarine Sunlight Viewable Display.

FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN DAMAGE TO YOUR EQUIPMENT/BOAT AND COULD     

INVALIDATE YOUR WARRANTY

Grounding the display

          

The power connection to the display should be made at either 
the output of the battery isolator switch, or at a DC power distri-
bution panel. Raymarine recommends that power is fed directly 
to the display via its own dedicated cable system and MUST be 
protected by a thermal circuit breaker or fuse, fitted close to the 
power connection. If you do not have a thermal circuit breaker or 
fuse in your power circuit, you MUST fit an in-line breaker or 
fuse to the positive red line on the power lead.
Refer to the following table for isolator switch circuit breaker or 
fuse value ratings and check all terminal connections are clean.

          

Extending the power cable

Longer power cable runs may require larger wire gauges to mini-
mize any voltage drop in the cable. Ensure that the minimum 
voltage specification of the display is met at the junction of these 
cables when the display is operating at full brightness.
If a longer power cable run is required, use the supplied power 
cable to connect the free end to the extension cable; take partic-
ular care to ensure correct polarity and grounding of the drain 
wire (shield) to the boat’s RF system. The supplied power cable 
has a cross section of 12 AWG (3.3 mm

2

). The maximum 

permissible lengths for extending a power cable are listed in the 
following tables: (

over the page

)

          

CAUTION

Grounding the display

An effective radio frequency (RF) and safety 

ground must be connected to the display. You 

must ground the display by connecting the drain 

wire (shield) of the power input cable to the 

nearest ground point of your boat’s RF ground 

system. This ground should not be connected to 

the boat’s battery or at any point other than the 

boat’s RF ground connection.

Boat’s 

power 

supply

Isolator 

switch 

minimum 

rating

Thermal 

breaker 

rating

Fuse value

12 V

15 A

8 A

12 A

24 V

8 A 

4 A

 6 A