16.1 Technical specification — EV-1 and EV-2
Nominal supply voltage
12 V (powered by SeaTalkng ® system).
Operating voltage range
10.8 V to 15.6 V dc.
Power consumption (taken from SeaTalkng ®
system)
30 mA.
SeaTalkng ® LEN (Load Equivalency Number)
1
Sensors
• 3-axis digital accelerometer.
• 3-axis digital compass.
• 3-axis gyro digital angular rate sensor.
Data Connections
• SeaTalkng ®.
• NMEA 2000 DeviceNet (EV-2 only; port not
used on EV-1 unit).
Environmental
Installation environment
• Operating temperature: -25 °C to +55 °C
(-13 °F to +131 °F).
• Storage temperature: -30 ºC to +70 ºC (-22°F
to +158°F).
• Relative humidity: max 93%.
• Waterproof rating: IPX 6.
Dimensions
• Diameter: 140 mm (5.5 in).
• Depth (including mounting enclosure): 35 mm
(1.4 in).
• Depth (including wall bracket): 95 mm (3.8 in).
Weight
0.29 kg (0.64 lbs)
EMC compliance
• Europe: 2004/108/EC.
• Australia and New Zealand: C-Tick,
Compliance Level 2.