2.9 Location and mounting
Site requirements
When planning the installation, take the following site requirements
into account.
AIS requirement
This product is NOT approved for use in hazardous/flammable
atmospheres. Do NOT install in a hazardous/flammable atmosphere
(such as in an engine room or near fuel tanks).
The AIS unit must be fitted in a location where it is not likely to be
stepped on or tripped over, and which:
• Is close enough to allow connection to the vessel’s VHF with the
3 ft (1 m) RF cable supplied.
• Is at least 3 ft (1 m) from an engine, compass or any magnetic
device.
• Has at least 6 in (100 mm) of clear space below, to allow access
for cabling and adequate cable bends.
• Is maintained at a temperature between -15°C (5°F) and +55°C
(130°F).
Unit dimensions
Item
Description
A.
150 mm (5.90 in)
B.
167 mm (6.57 in)
C.
50 mm (1.95 in)
D.
20.3 mm (0.8 in)
E.
99.5 mm (3.92 in)
F.
54 mm (2.12 in)
Mounting
Fitting the AIS unit
Note:
To ensure water resistance the unit must be mounted
vertically with the connectors facing down.