14
LifeTag Installation & Commissioning Guide
De-registering a Tag
If you want to de-register a Tag (for example, to use it with a different Base Station):
1. De-activate the Tag by switching off the associated Base Station then waiting for at least one
minute. When the Tag is inactive, the indicator should not show any indication.
2. Hold down the Tag button, and check that:
i.
The GREEN indicator lights.
ii. After 5 seconds, the RED indicator lights.
iii. After a further 5 seconds, the RED indicator flashes. The Tag is now de-registered.
3. Release the Tag button.
After a further few seconds, the Tag will automatically power down and the indicator will be unlit.
Note:
Before you can use a de-registered Tag, you must register it with the relevant Base Station.
3. Check that within the next 15 seconds, registration
starts. This is indicated by alternate RED and GREEN
LED flashes.
Note:
If registration does not start, switch the Base Station off
and on again, then repeat steps 2 and 3.
4. Wait for the alarm to ‘chirp’ 3 times, to indicate regis-
tration is complete. When the Tag is registered, the
Tag indicator briefly flashes GREEN once every
10 seconds, to show the Tag is active (i.e. in normal
operating mode).
In this condition, the Tag will initiate an alarm condi-
tion in the appropriate circumstances.
Alternate
RED and
GREEN
REGISTRATION START
D9041-1
GREEN Flashes
(Tag active)
REGISTRATION COMPLETE
D9042-1
RED LED Lit
GREEN LED Lit
Tag
DEREGISTERED
Tag
POWER OFF
RED LED Flashes
LED Unlit
5 seconds
5 seconds
60 seconds
D9043-1