WIRING

 

Modbus / MBus

 

Wiring Topology

 

Daisy Chain

 

Star Network

 

Modbus

 

ü

 

û

 

MBus

 

ü

 

ü

 

A | B

 

-

 

 1 | 2

 

Typical Modbus 
configura on shown

 

For MBus interface 
follow Wiring     
Topology below

 

500m Max,   ≤ 32 meters

 

 

 

 

 

Fuse class CC UL / fast ac ng 600V

 

Ra ng 0.5A                     

 

 

For ’Volt

-

free’ PLC or digital input,                                                         

voltage must be provided by the addi on  

of a DC PSU                                                      

 

Single Core

 

0.5 > 4mm

2

 

Ø 2.5mm max

 

Stranded

 

0.5 > 2.5mm

2

 

+

 

7mm

 

Ø 2.5 mm

 

0.8 Nm

 

Max

 

3P4W

 

3 CTs

 

1P2W

 

1 CT

 

2P3W

 

2 CTs

 

2 VTs

 

2P3W

 

2 CTs

 

3P3W

 

2 CTs

 

2 VTs

 

3P3W

 

2 CTs

 

3P4W

 

3 CTs

 

3 VTs

 

 

 

Voltage 
and current 
must be 
from same 

phase

 

Summary of Contents for RI-F200

Page 1: ...Rou ng of cables shall be way from any internal EMI source Copper cable should be used All wiring to be in accordance with applicable local standards Specifica ons Accuracy Wiring Input 3Ø 4 wire 3Ø 3 wire 2Ø 3 wire 1Ø 2 wire Voltage V L N and V L L 0 5 of full scale Rated Input Voltage 3x 11 300V AC L N 19 519V AC L L Current 0 5 of full scale Frequency Range 45 65Hz Frequency for L N 20V L L 35V ...

Page 2: ...ology below 500m Max 32 meters Fuse class CC UL fast ac ng 600V Ra ng 0 5A For Volt free PLC or digital input voltage must be provided by the addi on of a DC PSU Single Core 0 5 4mm2 Ø 2 5mm max Stranded 0 5 2 5mm2 7mm Ø 2 5 mm 0 8 Nm Max 3P4W 3 CTs 1P2W 1 CT 2P3W 2 CTs 2 VTs 2P3W 2 CTs 3P3W 2 CTs 2 VTs 3P3W 2 CTs 3P4W 3 CTs 3 VTs Voltage and current must be from same phase ...

Page 3: ...30 ü 14 14 Demand interval length 1 1 30 min ü 15 15 Max Auto Display Pages 21 1 21 ü 16 16 Change Page Sequence 1 21 No YES 1 21 ü 17 17 Pulse Weight 0 01 00 01 99 99 kWh imp ü 18 18 Pulse Dura on 0 1 0 1 2 0 Sec ü X 19 MBus Secondary ID Serial 0000 0000 9999 9999 ü 19 20 Factory Default No No Yes Does not reset energy demand values ü 20 21 Reset Energy No No Yes Password 1 ü Once entered reset e...

Page 4: ... www rayleigh com E sales rayleigh com Rayleigh Instruments Limited SP Z o o European Office Ul Aleje Jerozolimskie 214 Warsaw Poland 02 486 W www rayleigh pl E sales rayleigh pl E x1 9 Ac ve Energy kWh L1 IP L2 IP L3 IP L1 EP L2 EP L3 EP IP EP Net IP EP x10 18 Reac ve Energy kVArh L1 IP L2 IP L3 IP L1 EP L2 EP L3 EP IP EP Net IP EP x19 22 Apparent Energy kVAh L1 L2 L3 Hold 10 sec change Page Scroll...

Reviews: