Wuhan Raycus Fiber Laser Technologies Co., Ltd
User Guide RFL-QCW300/3000
29
4.6
Installation and Operation Instruction
a)
Particular care must be taken when taking out and installing the device.
Notice: Please make sure there is sufficient airflow that allows.
b)
Take off the protective cap and check the lens of optical fiber connector with bright
light for dust, dirt or damage before installing the device. Clean the lens first and put oc
the protective cap before the optical fiber connector is installed.
c)
Particular care must be taken when installing the feeding fiber as well as the fiber
connector. After installing the feeding fiber, take off the protective cap and check the
lens of optical fiber connector again to confirm whether it is clean and then install it.
d)
Connect electrical cables and connectors according to operating mode the user selected.
Make sure the input DC voltages are equal to the level noted in the specification.
e)
Supply 5V voltage to the pins 15 and 1 of the DB-25 interface connector and wait 10s
for the control system to activate. Connect the device with PC via RS-232 serial port or
Ethernet and start operating the device.
4.7
Software Instructions
The details of software instructions see
【
appendix 1-Software Instructions
】
.
4.8
Alarms and Solution
Some alarm may occur during operation. If any alarm occurs, the ALARM light (yellow) on
the front panel of the laser will light up and the laser will stop emitting and the alarm state can be
displayed on ―Raycus status‖ in Raycus software homepage. The instructions and solutions of
alarms are as follows: