4.

 

Operation Regulations 

4.1 Pre-inspection 

1)

 

Make sure the device appearance is  in good condition  and  the output fiber is  neither 

excessively bended nor broken.   

2)

 

Make sure signal line of laser and marking system are properly connected. 

4.2  1)

 

Starting procedures 

Please make sure the control  system  is on  before  you turn on the  fiber laser.  Only after at 

least 1 minute since the power turned on, the subsequent operations can be preceded.   

2)

 

Frequency set introductions   

For model P70Q, the frequency setting range is from 20 kHz to 100 kHz. 

For model P100Q, the frequency setting range is from 20 kHz to 200 kHz. 

3)

 

Laser marking checking   

For  the  device initial testing, first  turn  the power down to zero without turning  on  the 

marking system  after  the device is successfully  started. Then draw a quadrate, marking 

continuously while slowly increasing the power from zero to 100% at the same time. Meanwhile, 

use a ceramic material to observe the laser and the laser should become stronger, otherwise shut 

down the device and check. If operating normally, the marking system can be used in common 

order afterwards. 

4.3  Cautions 

1)

 

Marking frequency must be in the range of 20~100 kHz for P70Q, 20~200 kHz for P100Q. 

2)

 

It should not modulate the frequency while marking. 

3)

 

Stop marking first before shutting down the device, then turn the power down to zero and cut 

the power off. 

Summary of Contents for RFL-P70Q

Page 1: ...RFL P70Q P100Q 9 RFL P70Q P100Q...

Page 2: ...ium Pulsed Fiber Laser RFL P70Q P100Q Ver 2 0 Ytterbium Pulsed Fiber Laser User s Guide RFL P70Q P100Q Wuhan Raycus Fiber Laser Technologies Co Ltd 2018 Proprietary information All rights reserved Iss...

Page 3: ...re supplying the power to the device please make sure that the correct voltage of 24VDC power source is connected and the anode and cathode are right Failure to connect power source correctly will cau...

Page 4: ...al requirements and cautions 1 1 4 Specifications 2 2 Mounting 3 2 1 Mounting dimensions 3 2 2 Method of installation 3 3 Control Interface 5 4 Operation Regulations 8 4 1 Pre inspection 8 4 2 Operati...

Page 5: ...y Remark Fiber Laser module 1 1 3 Environmental requirements and cautions Pulsed laser should be driven by 24VDC 1V power source 1 Caution Make sure the corresponding wires of the device are properly...

Page 6: ...ut please stop marking at once to avoid further damage of the device 10 Power source sudden interruption will do great harm to the laser device Please make sure the power supply works continuously 1 4...

Page 7: ...Unit mm 2 Isolated output head dimensions As shown in Fig 2 Figure 2 Dimension drawing of output isolator Unit mm 2 2 Method of installation 1 Fix the module stable to the bracket and keep the laser...

Page 8: ...tches the laser and the control cable is well connected to the laser s interface The recommended electrical connection is shown in Fig 4 User s cont rolle r DB25 Controller interface Power supply wire...

Page 9: ...imum bit and D7 is maximum bit Range 0 255 hexadecimal 0X00 0XFF 10 13 15 24 25 Ground Digital GND 11 12 16 21 Laser alarms status See alarm codes in table 5 17 VCC 5VDC power supply input for indepen...

Page 10: ...s be high These pins indicate the following device states Table 5 Definition of alarm signal PIN 12 PIN 11 PIN 16 PIN 21 Alarm item Low Low Low Temperature alarm Low Low High Normal Low High Low Oblig...

Page 11: ...als are less than 3 mA The connection circuit of input and output signals is shown in Figure 6 Figure 6 Schematic of input and output signals 6 The control board and laser driver can be powered separa...

Page 12: ...z For model P100Q the frequency setting range is from 20 kHz to 200 kHz 3 Laser marking checking For the device initial testing first turn the power down to zero without turning on the marking system...

Page 13: ...cessive use or not following the instructions caused by those who are not from Raycus Customer has the responsibility to understand and follow this instruction to use the device Any damage caused by f...

Reviews: