5)
Do not install the collimating device into the output head when the laser device is in working.
6)
The device has three cooling fans at the rear panel to dissipate heat. In order to guarantee
enough airflow to help giving heat off, there must be a space of at least 10 cm’s width for
airflow in front and rear side of the device. As the cooling fans are working at blow condition,
if laser is mounted in a cabinet with fans, the direction should be same as laser’s fans.
7)
Do not look into the output head of the device directly. Please do wear appropriate laser
safety eyewear during the time when operating the device.
8)
Make sure the pulse repetition rate higher than 20 kHz.
9)
For the longest time without pulse is only 100 us. If there is no pulse output, please stop
marking at once, to avoid further damage of the device.
10)
Power source sudden interruption will do great harm to the laser device. Please make sure the
power supply works continuously.
1.4. Specifications
Table 2. 60M pulsed fiber laser specifications
NO.
Characteristic
Min
Typ.
Max
Uni
Remark
1
Central Emission
Wavelength
1060
1064
1085
nm
2
Polarization
Random
3
Nominal Average Output
Power
60
61.5
63
W
4
Pulse Repetition Rate
20
/
1000
kHz
5
Single pulse energy
/
/
1
mJ
may vary with pulse repetition
rate
6
Selectable pulse durations
10
/
350
ns
10 20 30 60 100 200 250 350
are optional
7
Output Power Tunability
10
/
100
%
8
Long-term average power
instability
<3%@24hrs
%
9
Beam quality M
2
/
1.6
/
M
2
10
Output beam diameter
6
7
8
mm
1/e
2
11
Guide Laser Power
Optional
12
Output Fiber Cable
/
2
/
m