Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-P500
11
CAUTION:
Please set the water temperature according to the
requirements above. Setting the temperature too high may cause an
abnormal performance; and liquid water may be condensed on the laser
module or the output head if a too low temperature is set, which may cause
serious damage to the device.
CAUTION
: The cooling system should be turned on first. Check any
water leakage and make sure that the water temperature reaches the set
point before start the laser. (25
±
1
℃
)
3.4
Installation rule
a)
Place the product in an appropriate position, immobilize it if necessary.
b)
Check if the power supply has the correct voltage (220V AC±10%
,
50/60Hz), and the earth line is connected, make sure it is firm and reliable.
c)
Connect the power cable and control cable to the product when power
supply is OFF.
d)
Clamp the water pipes ontopipe connector, run the chiller to check if there
is any leakage in the water circulation.
e)
Check the output head and clean it before installation. This procedure must
be performed by Raycus personnel or person authorized by Raycus.
f)
Prevent the delivery cable from treading, pinching or excessive bending
during installation.
g)
Make sure the environment is clean, or the output head may be
contaminated. It is prohibited to use fan during installation, which will
cause dust in the air.
h)
The minimum bending diameter of the transmission cable of the laser shall
not be less than 20cm in the non-working state (such as transport and
storage). The minimum bending diameter should not be less than 30cm
when the laser is work.