background image

Wuhan Raycus Fiber Laser Technologies CO., Ltd.

 

                                                                                                                                                                              20QS+/30QS

+Pulsed Fiber LaserUser’s Guide V1

 

 

f)

 

The  device  has  three  cooling  fans  at  the  rear  panel  to  dissipate  heat.  In  order  to 

guarantee  enough  airflow  to  help  giving  heat  off,  there  must  be  a  space  of  at  least 

10cm’s  widthfor  airflow  in  front  and  rear  side  of  the  device.  As  the  cooling  fans  are 

working  at  blow  condition,  if  laser  is  mounted  in  a  cabinet  with  fans,  the  direction 

should be same as laser’s fans. 

g)

 

Do  not  look  into  the  output  head  of  the  device  directly.  Please  do  wear  appropriate 

laser safety eyewear during the time when operating the device. 

h)

 

Make sure the pulse repetition rate higher than 30KHz. 

i)

 

For  the  longest  time  without  pulse  is  only  100  us.  If  there  is  no  pulse  output,  please 

stopmarking at once, to avoid further damage of the device. 

j)

 

  Power source sudden interruption will do great harm to the laser device. Please make 

sure the power supply works continuously. 

1.4.

 

Specifications 

Table 2.20QS+

30QS+pulsed fiber laser specifications 

Pulsed fiber laser 

20QS+ 

30QS+ 

Wavelength

nm

 

1060~1085 

1060~1085 

Polarization 

Random 

Random 

Optical isolator 

Yes 

Yes 

Nominal average output power (W) 

≥20 

≥30 

Single pulse energy (mJ) 

0.66@30kHZ 

0.75@40kHZ 

Beam quality

M2

 

<1.6 

<1.6 

Beam Diameter

mm

 

6

6

Pulse duration

ns

 

120-150@30kHZ 

130-160@40kHZ 

Pulse repetition rate

kHz

 

30-60 

40-60 

Output Power Tunability

%

 

10-100 

10-100 

Output Fiber Cable length

m

 

3.0 

3.0 

Working voltage

VDC

 

24±1 

24±1 

Power consumption

20

℃)(

W

 

150 

200 

Cooling 

Forced Air Cooled 

Forced Air Cooled 

Dimension W×D×H

mm

 

290*215*95 

290*215*95 

Operating temperature

(℃)

 

0

℃~

40

 

0

℃~

40

 

Store temperature

(℃)

 

-10

℃~

60

 

-10

℃~

60

 

humidity

%

 

30%~85% 

30%~85% 

Summary of Contents for RFL-P20QS+

Page 1: ...内部 A0 会签 阶段 标记 C RFL P20QS 30QS 20QS 30QS 激光器英文说明书 RFL P20QS 30QS JS02 部 门 脉冲激光器技术研究部 编 写 颜鹏晖 20210303 校 对 刘 红 20210305 审 核 李 科 20210305 标 审 李其军 20210305 批 准 黄 保 20210308 武汉锐科光纤激光技术股份有限公司 谢良 夏巨江 旧底图登记 号 底图登记号 ...

Page 2: ...User Instruction RFL P20QS RFL P30QS Wuhan Raycus Fiber Laser Technologies CO Ltd 2021 ...

Page 3: ...r device Before supplying the power to the device please make sure that the correct voltage of 24VDC power source is connected and the anode and cathode are right Failure to connect power source correctly will cause damage to the device b The device emits invisible 1060 1085nm wavelength light with average power20W 30W Do not expose your eyesor skin to the radiation of the laser c Do not take apar...

Page 4: ...3 Environmental requirements and cautions 1 1 4 Specifications 2 2 Mounting 3 2 1 Mounting dimensions 3 2 2 Method of installation 4 3 Control Interface 5 4 Operation Regulations 7 4 1 Pre inspection 7 4 2 Operation procedures 7 4 3 Cautions 7 5 Instructions for warranty return and maintenance 7 5 1 General warranty 7 5 2 Limitations of warranty 8 5 3 Service and repairs 8 ...

Page 5: ...tems Quantity Remark Fiber Lasermodule 1 1 3 Environmental requirements and cautions Pulsed laser should be driven by 24VDC 1V power source a Caution Make sure the corresponding wires of the device are properly grounded b All the maintenance to the device should only be done by Raycus because there is no replacement or accessory provided with the device Please do not try to damage the labels or op...

Page 6: ...here is no pulse output please stopmarking at once to avoid further damage of the device j Power source sudden interruption will do great harm to the laser device Please make sure the power supply works continuously 1 4 Specifications Table 2 20QS 30QS pulsed fiber laser specifications Pulsed fiber laser 20QS 30QS Wavelength nm 1060 1085 1060 1085 Polarization Random Random Optical isolator Yes Ye...

Page 7: ...er LaserUser s Guide V1 3 2 Mounting 2 1 Mounting dimensions a Fiber Laser module dimensions As shown in Fig 1 Figure 1 Dimension drawing of laser module Unit mm b Isolated output head dimensions As shown in Fig 2 Figure 2 Dimension drawing of output isolator Unit mm ...

Page 8: ...ow and green The definition figure is shown in Fig 3 Figure 3 Definition of power line wires c Make sure that the interface of the external controllermatches the laser and the control cable is well connected to the laser s interface The recommended electrical connection is shown in Fig 4 User s cont rolle r DB25 Controller interface Power supply wire Laser Module 24V Brown L N GND External GND 24V...

Page 9: ... 15 24 25 Ground Digital GND 11 12 16 21 Laser alarms status see alarm codes in the table below 17 VCC 5VDC power supply input for independent operation of the guide laser and PCB Maximum current consumption is 0 1A 18 EE Emission Enable EE signal HIGH Emission Enable LOW or disconnected Emission Disable 19 EM Emission Modulation EM input HIGH 3V Emission ON LOW or disconnected 1V Emission OFF 20 ...

Page 10: ...elow 1V are defined as digital Low The input current should be above 2mA d Alarms status Pins 11 12 16 and 21 are the alarm and status outputs which driven by 5V power from PIN 17 PIN 12 is reserved always be high These pins indicate the following device states Table 5 Definition of alarm status PIN 12 PIN 11 PIN 16 PIN 21 Alarm item Low Low Low Temperature alarm Low Low High Normal Low High High ...

Page 11: ...n to zero without turningon the marking systemafter the device is successfully started Then draw a quadrate marking continuously whileslowly increasing the power from zero to 100 at the same time Meanwhile use a ceramic material to observe the laser and the laser should become stronger otherwise shut down the device and check If operating normally the marking system can be used in common order aft...

Page 12: ...nstruction to use the device Any damage caused by fault operating is not warranted Accessories and fiber connectors are excluded in this warranty According to the warranty client should write to us within 31days since the defect is discovered This warranty does not involve any other party including specified buyer end user or customer and any parts equipment or other products produced by other com...