Control Interface
There are DB9 and DB25 interfaces at the rear of the laser. The DB9 is a RS232 interface
only used for debugging, no needs to connect. And DB25 is the joint interface connecting control
system with laser system, please make sure the connection is reliable before operation. Feet of
the DB25 are defined as follows in Fig. 5.
Figure 5. Connect port of controller
Table 3 Definition of connect ports of controller
PIN No.
Name
Description
1-8
(D0-D7)
Power Setting
8 bit Parallel port; D0 is minimum bit and D7
is maximum bit; Range: 0-255 (hexadecimal:
0X00-0XFF); 0 is minimum power and 255 is
maximum power.
10,13-15
,
24-25
Ground
Digital GND
11,12,16
,
21
Laser alarms status
see alarm codes in the table below
17
VCC
+5VDC power supply input for independent
operation of the guide laser and PCB
18
EE
Emission Enable (EE) signal.
HIGH: Emission Enable
LOW or disconnected: Emission Disable
19
EM
Emission Modulation (EM) input.
HIGH (>3V): Emission ON
LOW or disconnected (<1V): Emission OFF
20
Sync
Pulse Repetition Rate (Synchronization)
input, square wave.
22
Guide Laser signal
Guide Laser (red diode) ON/OFF input.
9,23
Obligate PIN
Reserved for Raycus only