Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C4000XZ~12000XZ
16
LASER
:
The power button of the laser main power supply has a green light indicator function.After
the laser main control system is powered on and all INTERLOCKs are detected as normal, press this
button, the laser main power supply is powered on, and the button lights up after the main power supply
is powered on.
ALARM
:
INTERLCOK alarm indication, the ALARM indicator lights up during the power-on
self-check on the control panel. After the self-inspection is completed, all INTERLOCK interfaces are
normally closed, and the ALARM indicator is off. During the operation of the laser, if any INTERLOCK
is disconnected and the laser preparation is not completed, the indicator light will be on.
STOP
:
Emergency stop button, press to turn off the main power of the laser immediately; turn the
button clockwise to release the button, and press the LASER button again to start the main power of the
laser.
INDICATOR LIGHT
:
After the main power supply of the laser is powered on, the green indicator
light is on when the laser is Ready; when the laser is emitting light, the red indicator light is on; when the
laser has a fault, the yellow indicator light is on, accompanied by an alarm sound.
4.2 Rear Panel
Figure 15 shows the rear panel.
Figure 15 Rear view of product panel.
①
②
③
④
⑤
⑥
⑦
⑧