Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C3300W~RFL-C15000W
24
The AC input lines of 3300W / 4000W two types laser use four-core cables,
and the AC input lines of
6000W /
8000W / 10000W / 12000W / 15000W four
types laser use seven-core cables. The interface definition and parameter
requirements of the AC input line are shown in Table 4.
Table 4 The interface definition and parameter requirements of AC input line.
Interface definition and parameter requirements of 3300W/4000W/6000W laser AC
input lines
Connector Tag
Interface
definition
Logo
Wire diameter
Wire
color
1
AC380V-L1
L1
6mm
2
/6mm
2
/10mm
2
Brown
3
AC380V-L2
L2
6mm
2
/6mm
2
/10mm
2
Black
5
AC380V-L3
L3
6mm
2
/6mm
2
/10mm
2
Gray
7
Protective
Earth
PE
6mm
2
/6mm
2
/10mm
2
Yellow
-green
2
、
4
、
6
、
8
/
/
/
/
Interface definition and parameter requirements of 8000W/ 10000W/ 12000W/
15000W laser AC input lines
1
、
2
AC380V-L1
L1
6mm
2
/6mm
2
/6mm
2
/10mm
2
Brown
3
、
4
AC380V-L2
L2
6mm
2
/6mm
2
/6mm
2
/10mm
2
Black
5
、
6
AC380V-L3
L3
6mm
2
/6mm
2
/6mm
2
/10mm
2
Gray
7
、
8
Protective
Earth
PE
6mm
2
/6mm
2
/6mm
2
/10mm
2
Yellow
-green
The standard length of 3.3kW / 4kW provided by Raycus is 8 meters, and the
standard length of 6kW / 8kW / 10kW / 12kW / 15kW is 15m.
4.4
Interface Definitions
All control signals are shown on the “INTERFACE” port located on the the
rear panel of the device. Figure 12 shows the control cord that we provide.