Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C3300W~RFL-C15000W
37
As shown in Figure 21, the user can view the current real-time water flow by
clicking on the read parameter in the whole machine view.
4.12
Real-time power feedback
For the RFL-C8000W/RFL-C10000W/RFL-C12000W laser, the real-time
power feedback function is added. When the laser emits, the real-time power of the
laser can be viewed by clicking the read parameter through the interface shown in
Figure 21.
4.13
Light out fault locking
The default setting of the "lighting fault lockout" parameter is “2”when the
laser is shipped from the factory. When using the laser, the “lighting abnormality”
alarm occurs twice in succession, the laser will automatically lock and cannot emit
light. Please contact Ruike related engineers for your timely resolution. As shown
in Figure 21 above, the default value is locked for the light fault.
5 Alarms and Possible Solutions
5.1
Read Alarm Logs
Whenever an alarm occurs when the laser is running, the laser stops emission and
is locked. At the same time the ALARM indicator (Yellow) on the front panel
lights on and one string of alarm log is sent at the serial port.
Use Raycus Client Software to read the alarm log(s). Opent the client
software
click ‘Read History Alarm Record’ tab
click ‘Read History Erro
Record’ button, to read and show the latest (up to 150) alarm logs.