![raycop VCEN-100 Operating Manual Download Page 15](http://html.mh-extra.com/html/raycop/vcen-100/vcen-100_operating-manual_789625015.webp)
15
Ho
w t
o U
se
PANTONE 7460C
Replacement of Consumables
Please make sure it is unplugged
and the power is turned off before
cleaning or replacing.
Warning
Release Lever
2
5
■Replacing the UV Lamp
※ If there is any defect within the first year,
the UV Lamp is covered by RAYCOP’s one-year warranty.
For more details contact customer support.
1
As shown on P.13, take out the grille.
By using a drive, remove the 5 screws
in order to take out the UV Lamp
Protective Tube.
Turn the UV Lamp release lever to
unlock.
Turn on the device and verify if the
UV Lamp is working properly by
checking the UV Lamp Indicator
Light.
3
Take out the UV Lamp set from the
release lever side.
4
In the reverse order of removing,
attach the release leaver in the new
UV Lamp set and fit the rubber into
the form. After hearing a click sound
and seeing the green point, turn it
into 90 degrees and attach it to the
device.
Caution
Take out the UV Lamp set from the
release lever side.
Release Lever
Protective Tube
UV Lamp
UV Lamp
Indicator Light