Rayburn STRATUS 75-30 XS Installation And Operation Instructions Manual Download Page 5

 

 

 
 
 

Carefully remove the appliance from the box. 
Prior  to  installing  the  appliance,  test  to  make  sure  the  appliance  operates  properly  by 
plugging the power supply cord into a conveniently located 230V electrical socket. 
Test  all  aspects  of  its  operation  (manual  switches,  remote  and  heater)  to  make  sure  all 

components operate correctly. 

As with most electronic devices, your new electric fireplace has been designed to operate at 
temperatures  between  5

℃ 

and  3

5

.  During  the  cold  winter  months,  allow  the  fireplace  to 

reach room temperature before turning it on.

 

NOTE:There  maybe  trace  of  odor  during  the  first  few  minutes  of  initial  use.This  is 
harmless, normal and will never occur again.

 

 

 
 

 

 

 

Plan where to locate and frame the fireplace. This will save time and money later when you 
install the fireplace. Before installation consider the following: 
1.  Where the fireplace is located must allow for wall and ceiling clearances. 
2.  Consider a location where the fireplace screen will not be exposed to direct sunlight from 

windows or doors. 

3.     

The  appliance  must  be  wired  into  a  separate  single  phase  power  supply  230V~50Hz, 

13amp fused spur. The fused spur/socket must be accessible at all times and must not 
be placed behind the unit. The mains socket must be accessible to ensure the appliance 
can be safely disconnected when required. 

4.   

On built in units the connection must be made using a 13 amp switched fused spur, the 

switch  must  be  accessible  at  all  times,  to  connect  to  a  fused  spur  trim  the  power  cord 
provided. 

WARNING – ELECTRIC SHOCK HAZARD 

It  is  the  customers  responsibility  to  contact  a  qualified 

electrical installer to make sure the electrical installation 

is adequate and in conformance with the regulations. 

Take  special  care  when  cutting  holes  in  walls  or  floor. 

Electrical wires may be behind the wall or floor covering 

and could cause an electrical shock if you touch them. 

Locate any electrical circuits that could be affected by the 

installation of this product and disconnect power circuit. 

 

 
 

 

 

WARNING: THIS APPLIANCE MUST BE EARTHED. 

DO NOT use an extension lead with this appliance. 

The  appliance  is  designed  for  the  voltage  stated  on  the 

data plate. 

Recommended  but  not  mandatory  to  fit  an  individual 

Residual  Current  Device  (RCD)  to  the  cooker  supply 

circuit. 

Hand  this  Manual  to  the  User  for  retention  and  instruct 

in the safe operation of the appliance. 

UNPACKING AND TESTING APPLIANCE

LOCATING THE FIREPLACE

Summary of Contents for STRATUS 75-30 XS

Page 1: ...n these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids...

Page 2: ...ndable and enjoyable service from your Rayburn product IMPORTANT INSTRUCTIONS 3 UNPACKING AND TESTING APPLIANCE 5 LOCATING THE FIREPLACE 5 STRATUS 100 30 XS 7 STRATUS 125 30 XS 8 SAFETY DRILL SCREW AR...

Page 3: ...13 Always use properly grounded fused and polarized outlets 14 Always use ground fault protection where it is required by electrical codes 15 Always disconnect the power before performing any cleaning...

Page 4: ...red to prevent it from being tipped over Always use a fire guard when young children and infirm persons can come into contact with the heater Don ts Never leave children unsupervised in a room where t...

Page 5: ...z 13amp fused spur The fused spur socket must be accessible at all times and must not be placed behind the unit The mains socket must be accessible to ensure the appliance can be safely disconnected w...

Page 6: ...s appliance has been tested in accordance with the EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 30 2009 A11 2012 EN 62233 2008 If you need assistance during installation please contact your local deal...

Page 7: ...is appliance has been tested in accordance with the EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 30 2009 A11 2012 EN 62233 2008 If you need assistance during installation please contact your local dea...

Page 8: ...appliance has been tested in accordance with the EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 30 2009 A11 2012 EN 62233 2008 If you need assistance during installation please contact your local deale...

Page 9: ...9 SAFETY DRILL SCREW AREA There is a safety drill screw area as show below Please make sure that the fix screws are in this area The manual control pad position Safety drill screw area Dark area...

Page 10: ...s are designed to be either built in or wall mounted depending on preference These units allow for the finishing material drywall stone tile etc to be built right down to the glass edge However should...

Page 11: ...11 2 Remove the optional trim from the unit as illustrated below Remove the wall framing plates from the unit 3 Re attach the framing plates to the unit as shown below...

Page 12: ...12 4 Bend the framing plates as shown 5 Lift the unit into the wall opening Note Two people are required...

Page 13: ...mounting screws through the flaming plates securing the unit into the wall studs 7 Using desired materials finish to the glass for a clean face installation OR re attach the steel surround that was re...

Page 14: ...the back of the fireplace by removing screws Select a location for the hanger to be fixed that is not prone to moisture and is located at least 0 91 m or 3 feet away from combustible materials such as...

Page 15: ...15 3 Fix the hanger onto the wall and put the fireplace on...

Page 16: ...16 4 Fix a bracket beneath the fireplace to ensure the fireplace won t move...

Page 17: ...miculite decorative media Unplug the unit from the power and make sure it is switched off Unscrew the adjustable screws to take off the front glass Pour the fire glass media into the try Feel free to...

Page 18: ...third time the heating element turns off indicator extinguishes Note after the heating elements are turned on manually the heating elements work but are not controlled by the temperature sensor 2 Pre...

Page 19: ...the remote control will turn off 2 Key flame and charcoal control switch In case of ON press once the flame and the charcoal bed go out the LCD screen does not display Press it again and the flame and...

Page 20: ...etween 7 and 30 The buzzer beeps when the key is pressed 9 Press shift key Press once the corresponding figure flashes Press now to set current time and week The buzzer does not beep when the key is p...

Page 21: ...displays icon the indicator on the machine lights yellow Press again to turn it off the LCD screen does not display icon and the indicator on the machine goes off The buzzer beeps when the key is pre...

Page 22: ...hemes which cater for the recovery and recycling of materials contained within Your co operation is vital to ensure the success of these schemes and for the protection of the environment 1 Switch off...

Page 23: ...184 FLAME EFFECT GLASS 1 6 9 601139B LED LIGHT LED3 23 2 2 0 2 6 9 601140B LED LIGHT LED3 33 2 2 4 4 7 3147504 3133504 3135504 FLICKER ASSEMBLY 1 8 10101221C FLICKER MOTOR 1 10 10702199 10702176 10702...

Page 24: ...24 EXPLODED VIEW...

Page 25: ...Wiring diagram 25...

Page 26: ...pliance to cool for 10 minutes then turn it on Circuit board is burnt out Inspect the circuit board and replace it if necessary No warm air coming out of appliance Heater is burnt out Inspect the burn...

Page 27: ...27 SERVICE HISTORY This heater must be serviced annually depending on usage NOTES Date Dealer Name Service Technician Name Service Performed Special Concerns...

Page 28: ...g your extended warranty period only genuine spare parts must be used in the servicing and maintenance of your stove these spare parts can be ordered via the Premium Retailer directly Consumable items...

Page 29: ...oduct fault or defect you must inform us within a reasonable amount of time this is within 14 days from the date on which the fault or defect first became apparent If the product fault or defect is no...

Reviews: