If the pilot is not already alight, light the pilot as described.
Slightly depress and turn the control knob anti-clockwise
from the pilot position to the maximum position ( ) (see
Fig. 5). The fire will ignite.
Adjust the heat output as required by turning the control
knob clockwise towards the minimum position ( ) (see
Fig. 6).
To ensure correct operation of the stove it is
recommended that it is
NOT
operated below the
minimum setting.
Close the control access door.
Turn the gas control knob to the minimum gas rate
position ( ) (Fig. 7), slightly depress the knob and
continue turning to the pilot position (
★
) (Fig. 8). The fire
will go out and the pilot will remain lit and may be left on
permanently.
When turning off appliance some ‘popping’ may occur,
this is quite normal as it is the residual gas being burnt
off.
Turn the stove off as described. Depress the control
knob, turn to the off (
●
) (Fig. 9) and the pilot will go out.
4
TO LIGHT THE STOVE
TO TURN THE STOVE OFF
TO TURN THE STOVE
AND PILOT OFF
FIG. 5
FIG. 6
FIG. 7
FIG. 8
FIG. 9