Rayburn 200 G User Instructions Download Page 2

Checks to ensure electrical safety should carried out by a
competent person.

Electricity Supply

WARNING: THIS APPLIANCE MUST BE EARTHED.

A 220/240V ~ 50Hz electrical supply is required near to
the appliance. The appliance is supplied with a 0.75m

2

3

- core 85ÞC rated PVC x 3m long replaceable power
supply cable having a label attached to the end of the
cable giving details of the cable core colour-coding and
their function, which should be adhered to. The appliance
must be protected by a 3 amp fuse if a 13 amp plug is
used.

For details of Programmer Wiring, see separate
Installation Instructions.

To connect a Plug

As the colour of the wires in the mains lead of this
appliance may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows:-

1.

The wire which is coloured green-yellow must be 
connected to the terminal in the plug which is 
marked with the letter E or by the earth symbol          
or coloured  green or green and yellow.

2.

The wire which is coloured blue must be connected 
to the terminal which is marked with the letter N or 
coloured black.

3.

The wire which is coloured brown must be connected
to the terminal which is marked with the letter L or 
coloured red.

Gas Safety Installation and Use

In your own interests and that of safety, it is the law that
all gas appliances are installed by a competent person in
accordance with the Regulations in force.

The whole gas installation, including the gas meter shall
be inspected and tested for soundness, and purged up to
the appliance gas cock.

When you light your cooker for the first time it may give
out a slight odour, this will soon disappear.

This appliance is fitted with combustion discharge safety
device (CDSD) which will switch off the appliance in
adverse flue conditions, therefore before turning the main
burners ensure that the manual reset button is depressed.
Fig. 1.

LIGHTING THE BURNER - SEE FIG. 1

1.

Switch OFF the electricity supply at the wall socket or
if the optional programmer is fitted ensure that it is 
switched to the OFF position.

2.

Ensure that the thermostat knob 

is at the O position

(Fig. 1).

3.

Open the outer door 

A

.

4.

Turn ON the service cock E (below the cooker burner
control valve) so that the line of the top of the service
cock E is in line with the pipework.

5.

Turn cooker burner control knob 

to the ignition 

symbol        and depress it fully (see Fig. 2).

6.

Keeping the cooker burner control knob 

depressed

fully, simultaneously press Piezo spark generator 

C

repeatedly until the pilot flame lights.

This is visible through the sight glass 

F

. (A few 

seconds must be allowed for the gas to reach the 
pilot burner). (See Fig. 1).

7.

Continue to hold down cooker burner control knob 

for at least 15 seconds after the pilot flame has lit, 
then release the knob slowly. The pilot flame should 
then remain alight.

IMPORTANT
If the flame does not remain alight, wait 3 
minutes and repeat the sequence, holding the 
knobs for a slightly longer time.

8.

Turn the cooker control

B

to the large main flame 

symbol        (See Fig. 2).

ELECTRICAL INSTALLATION

INSTRUCTIONS

2

Fig. 1

B - HOLD IN TO LIGHT - TURN

CLOCKWISE TO EXTINGUISH

A

OUTER DOOR

B

GAS CONTROL
VALVE KNOB

C

PIEZO

D

THERMOSTAT 
KNOB

E

SERVICE COCK

F

SIGHT GLASS
BURNER VIEWING
WINDOW

G MAIN BURNER
H

PILOT BURNER

J

MANUAL RESET
BUTTON

GAS

CONTROL

VALVE

Reviews: