Raybend RCP110 Use And Care Manual Download Page 1

HP

GPH of Water @ Total Feet of Lift

MAX 

Lift

1/20

0 ft

5 ft

10 ft

15 ft

18 

Feet

132

108

72

24

IMPORTANT!

READ ALL INSTRUCTIONS CONTAINED IN THIS MANUAL 

BEFORE USING THIS PRODUCT.

Save these instructions for future reference Failure to read and follow the 

warnings and instructions within this instruction manual could result in property 

damage, serious injury or death.

SPECIFICATIONS

Power supply:

115V, 60 HZ., 10 Amp Circuit

Liquid Temp. Range:

32°F to 95°F(0°-35°C)

Discharge:

3/8 in. Hose barb

Model #  RCP110

Condensate Pump

Use And Care Guide

Summary of Contents for RCP110

Page 1: ...IS PRODUCT Save these instructions for future reference Failure to read and follow the warnings and instructions within this instruction manual could result in property damage serious injury or death SPECIFICATIONS Power supply 115V 60 HZ 10 Amp Circuit Liquid Temp Range 32 F to 95 F 0 35 C Discharge 3 8 in Hose barb Model RCP110 Condensate Pump Use And Care Guide ...

Page 2: ...5 volts single phase 60 Hz and is equipped with an approved 3 conductor cord and 3 prong grounded plug Do not remove the ground pin under any circumstances The 3 prong plug must be directly inserted into a properly installed and grounded 3 prong grounding type receptacle Do not use this pump with a 2 prong wall outlet Replace the 2 prong outlet with a properly grounded 3 prong receptacle a GFCI ou...

Page 3: ...NT Ensure the electrical power source is adequate for the requirements of the pump IMPORTANT Before using the pump check the tubing for holes or excess wear which could cause leaks and ensure the tubing is not kinked or making sharp angles Straight tubing allows the pump to move the greatest amount of water quickly and also check that all tubing connections are tight to minimize leaks IMPORTANT Th...

Page 4: ...erfall pump Do not use where water recirculates Not designed for the drains of swimming pools NOTE This unit is non submersible The pump should not be installed in a manner that will subject it to flooding splashing or spraying Mounting the pump The tank has two slots 1 provided to mount the unit The slots are located on the back of the tank Mount the unit either on the side of the air conditioner...

Page 5: ...of the pump intake port Cut the tubing at an angle so that the bottom of the reservoir does not close the tubing outlet Be sure the tubing does not interfere with the float INSTALLATION Continued Connect the Tubing Connect the tubing from the pump discharge hose barb to the floor drain laundry tub or sink Leave an air gap above the tub drain ...

Page 6: ...rcuit to shut down the heating AC circuit The COM and NC switch contacts may be used to actuate a low voltage alarm circuit connected in series if the heating cooling system cannot be disrupted TESTING 1 Unplug the condensate pump so that it cannot pump out water Fill water into the pump reservoir until it is almost full The safety switch should activate before the float contacts the cover 2 Plug ...

Page 7: ...ruction in dis charge tubing 6 Blocked check valve 1 Straighten the tubing 2 Shorten the discharge tubing 3 Clean any debris from reservoir 4 Measure the height from the pump to the highest point Rework discharge if greater than 18 5 Check line for blockage and remove any debris 6 Remove any debris around check valve Liquid is drain ing back into reservoir from discharge line 1 Damaged check valve...

Page 8: ...hased outside of the United States including its territories and possessions outside of U S Military Exchange and outside of Canada This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of RAYBEND products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This Warranty shall be governed and construed unde...