Connecting the electronic unit 
 
There  are  two  push  buttons  on  the  electronic  unit  to  connect  it  to  the  mask.  Use  them  to  attach  the 
electronic unit to the mask. 

 

Charging the electronic unit 
 
Connect  the  charging  cable  to  the  electronic  unit.  Use  a  standard  USB  charger  (protection  class  II, 
CE/UL 5V/ minimum 30 mA). 

 

Putting the mask into operation

 RAY® Osmotex Active Sterilising Facemask® before each daily 

use

 

 
Step1: charge the electronic unit SC-10. With the electroncis unit SC-10 fully charged, the mask can be 
used for 10 hours. 
 
Step2: before usage the mask should be wetted at the outside, by rinsing in luke warm water under the 
tap or rinsing with a thoroughly wetted cloth after removing the electronic unit. 
  

  The  wetting  is  needed  in  order  to  for  the  immediate  onset  of  the  electrolytic  procees  and 

corresponding anti viral effect. If the mask is donned without pre-wetting, it will take about 30 half an 
hour before the desinfection process starts due to moisture from exrpiration.  
 

Please avoid direct contact between the electronic unit and moisture during when attaching it to 

the mask. In case it gets wet, it will automatically turn off, and can be used again (by switching on in the 
usual way) only after complete drying.  
 

Step3: put the mask on with or without the electronic unit SC-10, holding it against your cheek in order 
to cover nose and mouth. Adjust the shape of the nose clip with your hands. Fixate the mask by applying 
the elastic bands / earloops behind your ears. Wear the mask comfortably by adjusting the  lentght of 
the elastic bands by means of the stoppers. Assure that the mask sits firmly.   

  

Switching the electronic unit SC-10 on and off

 

 

 Please use only the supplied electronic unit for operating 
the  mask!  Please  charge  the  electronic  unit  completely 
before using it for the first time (see section Charging of 

the electronic unit). 

When the  electronic unit is fully charged,  press the  button to the 
right of the two LEDs for 1 second (see illustration). 

The  right  diode  lights  up  permanently  green.  The  mask  is  now 
supplied with permanent power and is activated. The fully charged 
electronic unit supplies sufficient current (operating voltage: 0.6 V) 
for at least up to 10 hours. 

To switch off the electronic unit, press the button for 1-2 seconds 
until the green LED goes off. The electronic unit is switched off and 
can be activated by pressing the button again.

  