M7 GX Technical Manual
57
Raveon Technologies Corp.
11. RV-M7 Diagnostic Provisions
11.1.
Overview of Diagnostics
Internal to the
RV-M7
radio modem, is a powerful 32-bit microprocessor. Along
with handing all aspects of radio modulation and demodulation, the microprocessor
also maintains an extensive array of diagnostic information.
This section details the diagnostic information available, and describes how to us
the information to optimize or troubleshoot a
RV-M7
radio network.
11.2.
Reading the Diagnostic Information
RV-M7
diagnostic information is read using AT commands, while the unit is in the
Command Mode. Refer to the section “User Serial Port Commands” to learn how
to put the
RV-M7
modem into the Command Mode.
To see a general overview of how the modem has been operating, us the
ATST
command (status request command), without any parameter. The radio modem
will respond with a list of certain operation statistics that it maintains. All statistics
start counting at 0. The ATST 1 command can be used to reset all statistics back
to 0, except the run-time timers.
Other operation and configuration statistics are available using the ATST
command, with a parameter to specify the desired statistic. The following table
describes the various statistics available.
11.3.
Status and Statistics Command
AT
Command
Command Description
Response
ST
General Communication Statistics – This command will cause the
RV-M7 to output a table of various operational statistics.
Statistics
overview screen
ST1
GPS Statistics – Statistics related to the GPS operation, if installed.
GPS Statistics
overview screen
ST2
Low-level internal statistics – Returns various low-level statistics.
These are subject to change in various firmware revisions.
Low-level
statistics screen
ST3
Compile date and time – Returns the data and the time that the
firmware was compiled.
Date and time
ST4
Run Time – Returns the amount of time that the modem has been
powered up and running.
Run time display
screen
ST9
Reset all statistics counters
OK