POWER LED
Charger plugged in
Battery Charged
Battery Low
Unit is OFF
No
OFF
YES
Solid green
Solid Orange
Unit is
ON
No
Green blink
10 second rate
Red blink
3 second rate
YES
Green blink
3 second rate
Orange blink
3 second rate
Battery failure detected
(See the Maintenance
Section)
No
Radio will not turn on
YES
Red Blink @Half second rate
Alert LED
While off during typical operation, this LED turns orange when an Alert condition is
being transmitted. When the alert is acknowledged over-the-air, this Alert LED will turn
green. This LED can only be turned off over-the-air to disable the alert alarm.
4.3
DC Power
DC power for the SM is connected to the 5-pin Lemo connector near the bottom-side
of the unit. Use the supplied cable to connect the DC power. The
red wire is
positive (+)
and the
black wire is negative (-)
.
The internal smart-battery electronics will charge and keep the battery charged as long
as DC is supplied. The DC input range is 10-15VDC and the charging supply should be
able to handle at least 2A.
The SM also has the ability to connect to a gang charger by means of three contacts on
the bottom of the radio shown below.
4.4
External Battery Port
The ATLAS PT
has the ability to connect to an external battery
pack for extended operation. The SM connects to this battery