13

 

Raveon Technologies Corp.

 

 

5.3.  Setting a Parameter 

To set a parameter in the 

TK8 

modem, enter the Command Mode as 

described above.  Then enter the proper AT command, a space, the 
parameter, and then a carriage return.  For Example, to set the address of the 

TK8 

modem to 1234, enter the following command: 

ATDT 1234

 <CR> 

Once a Parameter is changed, the modem will begin using the new 
parameter and the new parameter is saved to non-volatile.   

5.4.  Reading a Parameter 

To read the value of a particular setting, issue the command, with no 
parameter.  The modem will return the value followed by an “OK”.  The 
modem’s OK response is: 

The value in ASCII decimal format. 

A <CR>  <LF>  (<CD> = ASCII 0D,   <LF> =  ASCII 0A).  

An  “O”, “K”, <CR>, and <LF> sequence. 

For example, if the user enters the command to read the 

M8

’s

 modem 

address and its address was 1234, the user would issue the following 
command: 

ATDT

<cr>  

and the modem will respond with: 

1234 

<

CR

>  <

LF

>

  

OK

 

<

CR

>  <

LF

>

 

To get on-line help with a command, enter the command and put a question 
mark in for the parameter.  For example, to see what the ATDT command is 
for, type: 

 

ATDT ? 

The modem will respond by listing a brief description of the command.   To 
see a list of all commands, type 

HELP

.   

Many commands support the “

MIN

” and “

MAX

” parameters to read the 

minimum and maximum allowable settings.  For example, type 

ATJF MAX

 to 

find the maximum value the CTS negation threshold may be set to.  

5.5.  CONFIG Button 

If certain parameters within the modem are modified in a manor that causes 
the modem to cease functioning or if the user cannot enter the command 
m

ode via the “+++” method described above, there is a small push button 

internal to the 

TK8 

modem to assist in this case.   This CONFIG button may 

be pressed at any time, and forces the modem into a known operational state.  
The CONFIG button is located inside the modem. Remove the rear cover, 

Summary of Contents for TK8

Page 1: ...ompany Confidential 1 Raveon Technologies Corp TK8 RV M8S DART VHF UHF Data Modem Technical Manual Version E1 January 2015 Raveon Technologies Corporation 2320 Cousteau Ct Vista CA 92081 www raveon co...

Page 2: ...ror Bookmark not defined 7 1 Setting Cap Codes Error Bookmark not defined 7 2 Setting Paging Data Format Error Bookmark not defined 7 3 Numeric Messages Error Bookmark not defined 7 4 Alphanumeric Mes...

Page 3: ...ion Balance 24 11 6 RX Carrier Detect 25 12 Troubleshooting Error Bookmark not defined Symptom Unit will not receive Error Bookmark not defined Symptom Unit will not transmit Error Bookmark not define...

Page 4: ...ays or errors in data transmitted or received using Viper SC or for the failure of Viper SC to transmit or receive such data 1 3 Safety Warning Information Service This equipment should be serviced by...

Page 5: ...of this 1 5 Part 15 Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reaso...

Page 6: ...up to 57600 Small sized and single board construction Very efficient circuitry 700mW receiving 8W transmitting Easy to use Transmit data in Receive data out Easily configured using AT commands Extensi...

Page 7: ...t Loader is permanently installed inside the TK8 s microcontroller During power up it checks to see if the user wants to update the application program in the microcontroller The STAT1 pin is used to...

Page 8: ...ble input High 1 40V 3 2 Transmitter Specifications TK8 xx RF Power Output VHF 220Mhz 100mW 3 0 W programmable RF Power Output UHF 100mW 2 0 W programmable Maximum Duty Cycle 500mW 80 to 40C 20 to 60C...

Page 9: ...ifications Connector Type 20 pin 2mm header DC Input 10 28V volts DC DC power draw RX mode 600mW DC power draw TX mode 2W 11 W IO Voltage Levels 3 3V digital logic RX and TX data Transparent Async Wor...

Page 10: ...8 Sleep i CPU Sleep input 9 CTS O Clear to send output Indicates state of internal input buffer ATJF command sets the threshold where CTS is negated 10 RTS I RTS input for serial flow control 11 RSSI...

Page 11: ...ounting holes are provided on the module For best RF performance the TK8 module should be mounted to the system ground using metal stand offs 4 5 STAT LED Outputs An external dual color LED may be con...

Page 12: ...put into a Command Mode by entering a sequence of three plus characters To keep the TK8 modem from unintentionally entering the Command Mode because of the pattern occurring in a stream of data enter...

Page 13: ...as 1234 the user would issue the following command ATDT cr and the modem will respond with 1234 CR LF OK CR LF To get on line help with a command enter the command and put a question mark in for the p...

Page 14: ...FIG button is pressed and the IO port is RS232 it will revert back to the settings programmed into the TK8 modem once the Command Mode is exited 5 6 Exiting the Command Mode There are three ways to ex...

Page 15: ...ormal operation mode from Command mode If the CONFIG button inside the TK8 is pressed this parameter will be automatically set to 60000 Range 100 60000mS 60000 ATE Echo Character echo set on E1 or off...

Page 16: ...trength Indicator Returns the signal level of last received packet The reading is in dBm Usable for relative comparison of signals but absolute value is within10dB at 90dBm No parameters Returns a num...

Page 17: ...show the RF power output setting Value is in percent from 0 to 100 Use and RF wattmeter to confirm the power setting and adjust the accordingly to obtain the desired RF power level 0 100 100 ATR0 Symb...

Page 18: ...t 1 DNA 2 authorization status 3 connection status 4 base station ID 5 sequence 6 system ID 7 device class 8 LNA 9 home 10 communication state 20 GPS mode 21 1PPS count 22 GPS status 23 GPS features 2...

Page 19: ...Rx frequency in Hz or MHz c is 4 for control channel 0 for non control channels ab are the over the air modulation options a a is the bit rate index corresponding to the over the air bit rate to use...

Page 20: ...re is a pause in the data the modem will automatically key its transmitter and send the data over the air Serial Port Baud Rate While the TK8 modem is transmitting and receiving data on the DART netwo...

Page 21: ...g or diagnostic messages 1 DART and data reception related message will come out serial port 2 Verbose messages Mostly used for factory and engineering purposes SHOW Display an overview of the configu...

Page 22: ...o modem will respond with a list of certain operation statistics that it maintains All statistics start counting at 0 The ATST 1 command can be used to reset all statistics back to 0 except the run ti...

Page 23: ...e only setting that may require adjustment is the center frequency After years of operation all crystals will age and change frequency slightly The ATR8 command is used to adjust the center frequency...

Page 24: ...el 3 Read the frequency offset with the ATR8 command 4 Adjust the frequency to the center of the channel with the ATR8 command You can use the U key and the D key to change the settings up and down on...

Page 25: ...f it is above this value Carrier Detect is asserted The pre set value may be change with the ATRA command Note Asserted means low Negated means high The CD pin will sit at about 3 3V when CD is not as...

Page 26: ...Company Confidential 26 Raveon Technologies Corp Mode 3 CD OFF In this mode the CD pin is always negated...

Page 27: ...Company Confidential 27 Raveon Technologies Corp 12 Mechanical A drawing is shown below...

Reviews: