Supplied By www.heating spares.co Tel. 0161 620 6677
ESCAPE OF GAS
Should a gas leak be suspected, contact your gas
supplier without delay.
Do NOT search for gas leaks with a naked fl ame.
WARNING:
This appliance must be earthed. Do not touch
or tamper with this sealed unit or its components.
1.
INTRODUCTION
1.1 Please carefully read information given in the booklet to
help you again maximum control from your appliance
with minimum trouble and cost.
1.1.1
Your Ravenheat Condensing Low Nox Combination
Boiler has been designed to supply your Central
Heating and Domestic Hot Water directly from one
unit. When Central Heating is operating, the circulation
will be interrupted when Domestic Hot Water is being
drawn off.
This will normally not affect the level of Heating.
PLEASE NOTE
Due to the high effi ciency and resulting low fl ue gas
exhaust temperature a white plume of condensation
vapour (cool steam) will be emitted from the fl ue outlet
terminal, this is quite normal. It will be particularly evident
during periods of low outdoor temparatureor when the
boiler is working at its optimum performance
(Plume Management kit is available on request)
1.2
CLEARANCES AROUND THE BOILER
Above 125 mm ( 5 inches)
Below 150 mm ( 6 inches)
Front 450 mm (18 inches)
Sides 5 mm (0.2 inches)
25mm (1inch) in front when installed in a cupboard
1.2.1 Minimum clearences are required for safety and
maintenance. Do NOT obstruct any purpose made
ventilation opening if boiler has been fi tted in a
compartment.
Never hang clothes,ect, over the appliance
1.3
USER CONTROLS (Fig.1)
1.3.1
This appliance is designed to operate with the
minimum of attention by the User. All the controls
are to be found on the control pannel.
1.4 OPERATING SAFETY CHECKS TO PROTECT
YOUR APPLIANCE
1.4.1 Before lighting the Appliance check Central Heating
system pressure (Fig.1 item 7) is not less than 1
bar. If it is below this do not light but consult your
installer about refi lling your system as you may
have a leak in the system.
1.4.2 In the event of malfunction of the appliance will be
indicate by the relevant error code (Table1) on
Digital Display of the control panel (Fig.50).
These can be Reset by press a RESET button .
If lockout code persist leave the appliance shut
down and consult your installer/service
engineer immediately.
Table 1
USER’S GUIDE
CSI 120(T) Low Nox
(with or without built in timer)
CONDENSING LOW NOX SYSTEM INNOVATION SUPER HIGH EFFICIENTY AUTOMATIC
MODULATING COMBINATION BOILER FOR CENTRAL HEATING AND DOMESTIC HOT WATER
It is the law that all gas appliances are installed by
a competent person, in accordance with the gas
safety installation and use current regulations.To
the current Gas Safety (Installation and Use)
Regulations B.S.5440:2-(2000).
All CORGI registered installers carry a CORGI ID card and
have a registration number. Both should be recorded in your
boiler Log book. You can check your installer by calling
CORGI direct on 01256 732300
.
01: Lock out from the Flame Control Unit
02: Flue System obstruction
04: Overheat Lockout
06: Open or short circuit on Sanitary probe
12: Open or short circuit on Heating probe
14: Flame simulation on Flame Control Unit
17: Fault on Fan Control
28: Water Flow Switch Fault or low pressure
in the heating system
1