14.Use the supplied wire cutter to strip back the insulation on the lead wire and
connect the supplied male 1/4” quick disconnect terminal (P/N 405-2001-016).
15.Route the grey wire in the front panel to the red wire underneath the instrument
panel and connect the quick disconnect terminals.
16.Carefully replace the console front panel.
Note:
Do not replace the pump instrument panel until the “Viper Pro Firmware
Update” section on page 6 is completed.
Re-pin the Viper Pro Harness
The Viper Pro interface cable must be modified to take advantage of the
automatic power down feature on the field computer. Review the following
procedure to complete the installation of the field update kit.
1. Locate the round, 16-pin cable connector (female pins) disconnected from the
back of the Viper Pro.
2. Remove the two screws on the connector retainer and carefully unscrew the
shroud from the connector.
It may be necessary to use a set of pliers to help unscrew the connector. Be
careful not to damage the plastic connector or shroud.
3. While looking at the face of the connector, locate pin locations 2 and 14.
4. Insert the supplied Amp pin extractor tool (P/N 321-000-392) into the pin 2
location and depress the plunger to remove the pin.
16 Pin Interface
Connector