P/N 016-9001-022 Rev. D
17
VIPER 4
FIGURE 11. Disengage Calibration Screen
2. Turn the steering wheel. The following screen will appear:
FIGURE 12. Disengage Calibrating Screen
NOTE:
It may be necessary to increase the disengage setting on the pressure switch to require more steering
input to disengage SmarTrax and to decrease the disengage setting to require less steering input.
This adjustment can be made during the hydraulic system calibration or after the SmarTrax system
calibration. On flow switch systems, the system is either on or off and cannot be adjusted.
3. Proceed to the Engage Switch and Node Orientation section on page 19
continue with the SmarTrax system
calibration.
SMARTRAX SYSTEMS WITH A PRESSURE TRANSDUCER INSTALLED
IMPORTANT:
This section applies only to SmarTrax systems utilizing pressure transducers to disengage the SmarTrax
system when the steering wheel is turned. If a pressure or flow switch is installed in the SmarTrax, system,
refer to the SmarTrax Systems with a Pressure or Flow Switch Installed section on page 16 to calibrate the
SmarTrax system.