CAN Sidekick Pro Injection for Case IH 3/4XXX Installation and Operation Manual
Off Rate Percent.
Enter the initial off rate as 30%. The off rate percent sets the allowable difference between the
target and actual product application rates. If a non-zero value is entered for this setting and the difference
between target and actual rate exceeds the set value for longer than five seconds, ROS will display an off rate
alarm for the operator.
FER Cal.
Enter an initial FER value of 6. The FER (Flow to Encoder Ratio) error cal value is used to set the flow error
tolerance of chemical injection applications. Increase the FER error cal value to set a tighter tolerance. Set the
FER error cal to zero to turn off all flow monitor alarms for the injected chemical.
NOTE:
The range for the FER error cal is 0 through 9. The default value for a Sidekick Pro injection pump is 6.
Enable Maximum Vacuum Error.
Enable the vacuum error to provide an alert to the operator if the injection
pump cannot draw product from the chemical supply tank. Review the pump troubleshooting information, or
contact a local Raven dealer for additional assistance with vacuum alarm conditions.
Enable Flow Alarm Enable.
Enable the flow alarm to display an alert if ROS does not receive a signal from the
pump flow switch. This alarm may be used to help troubleshoot flow errors with a CAN motor control node.
This alarm can not be disabled on CHN injections systems.
Enable Zero Speed Shutoff.
Enable the zero speed shutoff feature to allow ROS to automatically shut off product
application if the vehicle speed is slower than 0.7 mph [1.1 km/h]. If the zero speed shutoff feature is engaged
during a job, the device will also display a zero speed alert to the operator.
NOTE:
The zero speed shutoff feature only affects products set to automatic control. Products controlled
manually will continue to be applied even if the zero speed shutoff feature is engaged.
To restart product application after the zero speed shutoff feature has been engaged, cycle the master switch
‘Off’ and then back ‘On.’ The zero speed shutoff feature will reactivate if the vehicle does not achieve a speed
greater than 0.7 MPH [1.1 km/h] and maintain that speed for more than 10 seconds.
Enable Maximum Pressure Error.
Enable the maximum pressure error feature to enable operator alarms for the
Sidekick Pro injection pump. The maximum pressure alarm will be displayed if the pump outlet pressure
reaches 150 PSI [1034 kPa].
Enable Low Pressure Error.
Enable the low pressure error feature to enable operator alarms for the Sidekick Pro
injection pump. The minimum pressure alarm will be displayed if the pump outlet pressure falls below the
monitored boom pressure for longer than 5 seconds.
NOTE:
A pressure transducer must be installed and connected to the carrier product control channel to
monitor the boom pressure.
SIDEKICK PRO™ INJECTION PUMP PRIMING AND CALIBRATION
CALIBRATION TAB
NOTE:
The Injection Calibration tab will be available only when interfacing with a Sidekick Pro injection
system.
To access the Injection Calibration tab:
1. Touch the Edit icon in the Machine Panel to view the Machine Devices.
2. Locate and select the Product Control button.
Edit
Product
Injection
Summary of Contents for Sidekick Pro
Page 12: ...CHAPTER 2 10 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...
Page 84: ...CHAPTER 7 82 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...
Page 88: ...CHAPTER 8 86 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...
Page 91: ...System Diagrams Electrical 89 SYSTEM DIAGRAMS FIGURE 2 Single Pump System Diagram ...
Page 93: ...System Diagrams Electrical 91 SYSTEM DIAGRAMS PLUMBING FIGURE 4 Dual Pump Injection Plumbing ...
Page 96: ...Index 94 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...