background image

Starting the M4x Blade Software

 

1. 

Verify the M4x Blade is powered on 

2. 

Connect the USB Cable to the M4x Blade as well as to the 
computer 

3. 

Located on the Computer Desktop, select “M4x Setting” 
shortcut 

4. 

Once the program is open, select “Actions” menu in the 
upper left are of the screen 

5. 

Select “Connect” 

6. 

Select “Local/USB” 

7. 

On the right-hand side of the screen, a new box will appear 

8. 

Press the “+” next to Communication System 

9. 

Click on “Blade” and factory settings will appear 

 

This screen will show the following: 

The M4x Blade Firmware Revision 

The Modules Installed / Firmware Revision 

Any enabled features 

10.  Click on the “+” next to Blade (and its Node Address) 

The items that appear will allow you to access the port 
settings 

11.  Click on the “+” next to System Voting to create a Vote 

Group or Groups (an optional feature) 

12. 

Click on the “+” next to System Bridging to create a Bridge 
Group or Groups 

Please refer to the M4x User Manual for more detailed settings. 

Configuring the M4x Analog 4-Wire Module

 

1. 

Click on the “+” just to the left of the Blade, if you haven’t 
already from prior instructions.  All ports populated will 
show a generic name until the user changes it. 

2. 

Click on the port that you want to analyze or configure.  The 
Port Status, along with the Transmit and Settings control 
buttons appear. 

3. 

Press the Settings button in order to expand the settings 
screen. 

4. 

Click through the tabs to see various settings. 

5. 

When all changes have been made, click “Actions” menu 
and then “Save Settings to Firmware”.  This will save the 
settings to the M4x Blade.  Please note: the “Save” button, 
only saves the changes on the computer and will not save 
the settings onto the M4x Blade. 

6. 

After any changes have been made, please power cycle the 
M4x Blade by unplugging the unit and plugging it back in. 

Configuring a Bridge

 

1. 

Configure the M4x Analog 4-Wire Module(s) before 
configuring a Bridge. 

2. 

The M4x Blade allows multiple bridge configurations to be 
created on one blade. 

3. 

Click “System Bridging” on the right side of the screen. 

4. 

Drag various ports from the system components panel and 
drop them onto the Port Name boxes in the Bridge 
Configuration pop up box. 

If Broadcast is NOT checked, the associated 
bridge group will be full conference. 

If DTMF Bridge Group is enabled, the members of 
the bridge are now able to be cross-patched 
dynamically as remote users dial using DTMF-
enabled devices. 

Please refer to the M4x User Manual for more detailed settings. 

5.  Click the check box “Enabled” to enable the bridge. 

Configuring SNR Voting (Advanced Feature)

 

1. 

Configure the M4x Analog 4-Wire Daughter Board(s) before 
configuring a Vote Group. 

2. 

Click “System Voting” on the right side of the screen. 

3. 

Follow the wizard that appears. 

4.  Click the “Add” button to enable the Voting group. 

Performing an M4x Loop Back Test for a  

4-Wire Analog Module

 

The M4x Loop Back Test  enables users to perform basic tests 
for PTT and COR, XMT and RCV tones, as well as DTMF. 

1.  Click “Actions” on the Menu (upper left corner of screen) 

2.  Select “Loop-back Test” 

3.  Place the loopback cable firmly into a M4x Blade port to test. 

4.  Select the port to test (be sure the cable is in the same port) 

5.  Select the Loopback Tab 

6.  Select to Test All or the Specific Test and click Test 

7.  Testing status and Pass/Fail notifications will populate as 

the M4x Blade goes through the specified tests. 

 

 

 

Thank you for  choosing  a Raven  Electronics  M4x  Blade  for 
your  Communication  needs,  where  we  are  the  idea  shop 
committed  to  solving  engineering  problems  and  exceeding 
expectations. 

Rev: E  2011 

Raven Electronics Corporation   4655 Longley Lane, Reno, NV  89502       Main: 775.858.2400   Sales: Press 2  Technical Support: Press 3      Fax: 775.858.2410 