016-0230-129 Rev. B
17
HYDRAULIC SYSTEM INSTALLATION
FIGURE 2. AutoBoom Valve Mounted on the Sprayer
2. Secure the mounting bracket to the machine center rack using two 2-9/16” W x 3-1/2” L x 3/8” thread U-bolts
(P/N 107-0171-616) and four 3/8”-16 zinc flanged lock nuts (P/N 312-1001-164).
NOTE:
Mount the AutoBoom valve so that Port P is facing up and LC and RC Ports are facing the center of
the machine.
INSTALL THE PRESSURE AND TANK HOSES
WARNING
Hydraulics are under pressure. Care should
always be taken with a system that has been
pressurized. When disconnecting or purging
hydraulic hoses, be aware that the hydraulic fluid
within the machine system may be extremely hot
and under high pressure.
CAUTION
When installing AutoBoom hydraulics or
performing diagnostics, maintenance, or routine
service, ensure precautions are taken to prevent
any foreign material or contaminants from being
introduced into the machine hydraulic system.
Objects or materials that are able to bypass the
machine hydraulic filtration system will reduce
performance and possibly cause damage to the
AutoBoom hydraulic valve.