1.2.10
MOUNTING THE WHEEL ANGLE SENSOR
Figure 15 and Figure 16 show a detailed view of the
structure of a wheel angle sensor assembly. Table 1
also lists the components shown in Figure 15.
Symbol Description
1
Sensor housing
2
Sensor disc
3
Mounting bracket 3mm
4
Mounting strip 20x 3mm
5
2 x M5 x 16mm (countersunk
head)
6
2 x M5 x 30mm
1.
When the front wheels are in straight position,
the screws of the sensor housing and sensor
disc should be aligned with the front axle. It is
also important that the sensor disc is rotated in
such a way that the triangles in the disc and
the sensor housing (Figure 17) are properly
aligned. Only then will the wheel angle sensor
produce a voltage reading.
2.
The sensor housing and sensor disc should be
aligned EXACTLY on the pivot point of the stub
axle. The centre-to-centre distance of the
mounting holes is 28 mm.
Please note!:
At all times the triangles on the sensor housing
and sensor disc must be pointing in the same
direction!
TABLE 1 WHEEL ANGLE SENSOR COMPONENTS.
FIGURE 15 SCHEMATIC OVERVIEW OF WHEEL
ANGLE SENSOR WITH MOUNTING BRACKET
AND STRIP
FIGURE 16 SCHEMATIC DRAWING OF WHEEL
ANGLE SENSOR WHEN MOUNTED